EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Anatase–Gentamicin Electrophoretic Coatings on Polyurethane‐Modified Titanium: Antibacterial Performance, Biocompatibility, and Drug Delivery

Fabiola A Gutiérrez-Mejía iD, Rossana F Vargas-Coronado iD, Claudia Vásquez-López iD, Luis Díaz-Ballote iD, Claribel Huchin-Chan iD, Fabiola E Villa-de-la-Torre iD, Victor E Arana-Argaez iD, Raúl Rosales-Ibáñez iD, Arely M González-González iD, Raymundo Cruz-Pérez iD, Juan V Cauich-Rodríguez iD

International Journal of Biomaterials · 2026-01 · 2026 (1)

DOI: 10.1155/ijbm/7643259 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Biomaterials, online erschienen am 28.04.2026. Verfasst von Fabiola A Gutiérrez-Mejía und 10 weiteren Autor:innen. Beteiligte Einrichtung: Materials Department, Centro de Investigación Científica de Yucatán (CICY), Mérida, Yucatán, Mexico, cicy.mx. Die Arbeit nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Consejo Nacional de Ciencia y Tecnología.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Infections, limited biocompatibility, and material degradation remain major challenges for metallic implants in biomedical applications. To address these issues, this study presents a multifunctional coating strategy for Grade 2 titanium using a base layer of segmented polyurethane (Tecoflex SG‐80A), followed by the co‐deposition of titanium dioxide nanoparticles and gentamicin sulfate. Corrosion polarization tests revealed enhanced passivation of polyurethane‐coated surfaces with no signs of pitting corrosion. Coatings showed porous microstructures with both nanoparticles and antibiotics distributed within and along pore edges. Energy‐dispersive X‐ray spectroscopy (EDX) confirmed the surface presence of both components. Thermogravimetric analysis indicated loadings of 0.17 ± 0.02 mg of gentamicin and 0.30 ± 0.04 mg of TiO 2 per specimen. SEM and AFM analyses showed that over 86% of the surface was covered with gentamicin and nanoparticles. Contact angle measurements revealed a hydrophilic character (35°) for coatings containing both gentamicin and TiO 2 nanoparticles, favorable for biological interactions. Cytotoxicity assays using dental pulp mesenchymal cells and fibroblasts demonstrated no cytotoxic effects after 72 h, whereas antibacterial tests against Staphylococcus aureus and Escherichia coli indicated inhibitory effects. Gentamicin release from the coatings followed the Korsmeyer–Peppas model, suggesting a diffusion‐driven profile. These results support the development of durable, biocompatible, and antibacterial coatings for titanium implants that can reduce infection risk, enhance corrosion resistance, and support tissue integration.

Schlagwörter

Stichwörter der Autor:innen

anatasebiocompatibilityelectrophoretic depositiongentamicinsurface coatings

Autor:innen und Institutionen

  • Materials Department, Centro de Investigación Científica de Yucatán (CICY), Mérida, Yucatán, Mexico, cicy.mx.
  • Physics Department, Universidad de Sonora (UniSon), Hermosillo, Sonora, Mexico.
  • Applied Physics Department, Centro de Investigación y Estudios Avanzados del IPN Unidad Mérida (CINVESTAV), Mérida, Yucatán, Mexico.
  • Chemistry Faculty, Universidad Autónoma de Yucatán (UADY), Mérida, Yucatán, Mexico.
  • Laboratory of Tissue Engineering and Translational Medicine, Faculty of Higher Education Iztacala, National Autonomous University of Mexico (UNAM), México City, Mexico, unam.mx.
  • Research Laboratory in Nano and Dental Biomaterials, Faculty of Higher Studies Iztacala, National Autonomous University of Mexico (UNAM), México City, Mexico, unam.mx.

ORCID-Profile: Fabiola A Gutiérrez-Mejía, Rossana F Vargas-Coronado, Claudia Vásquez-López, Luis Díaz-Ballote, Claribel Huchin-Chan, Fabiola E Villa-de-la-Torre, Victor E Arana-Argaez, Raúl Rosales-Ibáñez, Arely M González-González, Raymundo Cruz-Pérez, Juan V Cauich-Rodríguez

Förderung

  • Consejo Nacional de Ciencia y Tecnología

Zitieren

APA

Gutiérrez-Mejía, F. A., Vargas-Coronado, R. F., Vásquez-López, C., Díaz-Ballote, L., Huchin-Chan, C., Villa-de-la-Torre, F. E., Arana-Argaez, V. E., Rosales-Ibáñez, R., González-González, A. M., Cruz-Pérez, R., & Cauich-Rodríguez, J. V. (2026). Anatase–Gentamicin Electrophoretic Coatings on Polyurethane‐Modified Titanium: Antibacterial Performance, Biocompatibility, and Drug Delivery. International Journal of Biomaterials, 2026(1). https://doi.org/10.1155/ijbm/7643259

Vancouver

Gutiérrez-Mejía FA, Vargas-Coronado RF, Vásquez-López C, Díaz-Ballote L, Huchin-Chan C, Villa-de-la-Torre FE, et al. Anatase–Gentamicin Electrophoretic Coatings on Polyurethane‐Modified Titanium: Antibacterial Performance, Biocompatibility, and Drug Delivery. International Journal of Biomaterials. 2026;2026(1). doi:10.1155/ijbm/7643259

BibTeX
@article{GutirrezMeja2026,
  author = {Gutiérrez-Mejía, Fabiola A and Vargas-Coronado, Rossana F and Vásquez-López, Claudia and Díaz-Ballote, Luis and Huchin-Chan, Claribel and Villa-de-la-Torre, Fabiola E and Arana-Argaez, Victor E and Rosales-Ibáñez, Raúl and González-González, Arely M and Cruz-Pérez, Raymundo and Cauich-Rodríguez, Juan V},
  title = {Anatase–Gentamicin Electrophoretic Coatings on Polyurethane‐Modified Titanium: Antibacterial Performance, Biocompatibility, and Drug Delivery},
  journal = {International Journal of Biomaterials},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/ijbm/7643259}
}
Kostenlos starten →