EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improvement of Dosimetry Planning in 3D Conformal Radiotherapy for Breast Cancer With Lymph Nodes Using the High‐Tangential Tilted‐Supraclavicular Technique

Mazen Moussallem iD

International Journal of Breast Cancer · 2026-01 · 2026 (1)

DOI: 10.1155/ijbc/2650553 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Breast Cancer, online erschienen am 15.04.2026. Verfasst von Mazen Moussallem. Beteiligte Einrichtung: Research and Development Department, Healthy Innovations, Rachiine, Zgharta, Lebanon. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Despite the emergence of advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT), three‐dimensional conformal radiotherapy (3DCRT) continues to be used due to its advantages in treating breast cancer. This study aimed to optimize the 3DCRT technique for breast cancer cases that require lymph node irradiation. Methods and Materials A total of 100 consecutive patients were included. For the first 50 patients, standard (ST) 3DCRT dosimetry plans were prepared. For the remaining 50 patients, plans were generated using an optimized High‐tangential Tilted‐supraclavicular (HT) technique, which consists of tilting the supraclavicular beam to reduce ipsilateral lung irradiation; raising the tangential fields superiorly to enhance coverage of axillary levels I and II; and intentionally creating an internal overlap between the supraclavicular and tangential fields. This overlap was resolved using the field‐in‐field (FIF) technique, primarily applied to the supraclavicular field, which is the main contributor to ipsilateral lung dose in this region.

Results

The HT technique demonstrated promising results compared with the ST technique and other published 3DCRT methods. It achieved improved coverage of axillary levels I and II while reducing the dose to the ipsilateral lung. However, further adjustments are needed to enhance coverage of axillary level III, the supraclavicular region, and internal mammary nodes (IMN). These include the following: completing targets contouring prior to dosimetry planning to enable precise field adjustments; relaxing the 2 cm constraint on ipsilateral lung irradiation by tangential fields when IMN is included; relaxing the maximum dose constraint for the supraclavicular and IMN fields; and using a fully electron‐based field instead of a mixed electron‐photon technique for IMN dedicated field.

Conclusions

The HT technique was quantitatively validated, and a modified version was proposed and qualitatively assessed. This new version may be considered for clinical use, and comparison with VMAT in a larger patient cohort is recommended.

Schlagwörter

Stichwörter der Autor:innen

3DCRTbreast cancerdosimetry planninglymph nodes

Autor:innen und Institutionen

  • Research and Development Department, Healthy Innovations, Rachiine, Zgharta, Lebanon.
  • Radiotherapy Department, Centre de Traitement Médical du nord, Zgharta, Lebanon.
  • Medical Imaging Department, Holy Family University, Batroun, Lebanon, holyfamily.edu.

ORCID-Profile: Mazen Moussallem

Zitieren

APA

Moussallem, M. (2026). Improvement of Dosimetry Planning in 3D Conformal Radiotherapy for Breast Cancer With Lymph Nodes Using the High‐Tangential Tilted‐Supraclavicular Technique. International Journal of Breast Cancer, 2026(1). https://doi.org/10.1155/ijbc/2650553

Vancouver

Moussallem M. Improvement of Dosimetry Planning in 3D Conformal Radiotherapy for Breast Cancer With Lymph Nodes Using the High‐Tangential Tilted‐Supraclavicular Technique. International Journal of Breast Cancer. 2026;2026(1). doi:10.1155/ijbc/2650553

BibTeX
@article{Moussallem2026,
  author = {Moussallem, Mazen},
  title = {Improvement of Dosimetry Planning in 3D Conformal Radiotherapy for Breast Cancer With Lymph Nodes Using the High‐Tangential Tilted‐Supraclavicular Technique},
  journal = {International Journal of Breast Cancer},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/ijbc/2650553}
}
Kostenlos starten →