Analysis of the Influence of Arc Contact Ablation and Arcing Time on the Gas Flow Characteristics of SF 6 Circuit Breakers

Xue Zhang, Bin Xiang, Shulei Zhao, Chuxin Wang, Yixuan Li, Zhiyuan Liu

International Transactions on Electrical Energy Systems · 2026-01 · 2026 (1)

DOI: 10.1155/etep/3938543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Transactions on Electrical Energy Systems, online erschienen am 28.04.2026. Verfasst von Xue Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Shanghai Municipal Electric Power Company.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High‐current interruptions aggravate arc contact ablation, and arcing time strongly influences the gas‐blast capability of self‐energy SF 6 circuit breakers. This study quantifies the effect of arcing time on gas flow characteristics while accounting for cumulative arc contact ablation over repeated operations. A T100a test is performed on a 40.5 kV/31.5 kA self‐energy SF 6 circuit breaker, and an enthalpy‐flow model is established and validated against measurements. Numerical analyses are then conducted for 1–11 interruption operations. The pressure in the expansion chamber at the current zero crossing ( P cz ) increases first and then decreases with increasing arcing time, and longer arcing times lead to a larger P cz drop after repeated operations. After 11 operations, P cz decreases by 52.14% at 22.5 ms ( τ = 75 ms) and by 60.33% at 23.9 ms ( τ = 120 ms). The P cz drop percentage exhibits a quadratic dependence on arc energy, with fitted coefficients increasing with operation count. Overall, an arcing time window of 9.6–20 ms provides the best compromise between interruption margin and cumulative degradation in this study.

Förderung

  • State Grid Shanghai Municipal Electric Power Company

Zitieren

APA

Zhang, X., Xiang, B., Zhao, S., Wang, C., Li, Y., & Liu, Z. (2026). Analysis of the Influence of Arc Contact Ablation and Arcing Time on the Gas Flow Characteristics of SF 6 Circuit Breakers. International Transactions on Electrical Energy Systems, 2026(1). https://doi.org/10.1155/etep/3938543

Vancouver

Zhang X, Xiang B, Zhao S, Wang C, Li Y, Liu Z. Analysis of the Influence of Arc Contact Ablation and Arcing Time on the Gas Flow Characteristics of SF 6 Circuit Breakers. International Transactions on Electrical Energy Systems. 2026;2026(1). doi:10.1155/etep/3938543

BibTeX
@article{Zhang2026,
  author = {Zhang, Xue and Xiang, Bin and Zhao, Shulei and Wang, Chuxin and Li, Yixuan and Liu, Zhiyuan},
  title = {Analysis of the Influence of Arc Contact Ablation and Arcing Time on the Gas Flow Characteristics of SF 6 Circuit Breakers},
  journal = {International Transactions on Electrical Energy Systems},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/etep/3938543}
}
Kostenlos starten →