Thermo‐Economic Assessment of Grey‐Water Heat Recovery Using Multi‐Tube Heat Exchangers
International Journal of Energy Research · 2026-01 · 2026 (1)
DOI: 10.1155/er/8416976 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Energy Research, online erschienen am 08.07.2026. Verfasst von Moaz Al-lehaibi und 6 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Umm Al-Qura University.
Abstract (Originalsprache)
Background
Domestic grey‐water carries recoverable thermal energy that can meaningfully reduce hot‐water demand, yet most commercial drain‐water heat‐recovery (DWHR) devices use single‐tube layouts that trade thermal performance against hydraulic losses and rarely undergo joint energy–economic appraisal.
Methods
We conduct a comprehensive two‐E (energy and economy) assessment of a vertical multi‐tube heat exchanger (MTHE) intended for shared building drain stacks in multi‐unit residential, hotel, dormitory or similar centralised domestic hot‐water applications. A full‐factorial sweep of six variables—tube count ( n = 2−4), inner diameter ( D i = 13−25.4 mm), length ( L = 2−4 m), hot‐ and cold‐water mass‐flow rates (–3.5 kg s −1 and –2 kg s −1 ) and hot‐stream inlet temperature ( T h ,in = 303−333 K)—yields 3 × 2 × 2 × 4 × 4 × 3 = 576 steady‐state cases. Heat‐recovery rate q , cold‐side outlet temperature T c ,out , annual savings, 10‐year net present value (NPV) and discounted payback period (DPP) are computed using a validated overall heat‐transfer correlation and a cold‐side pressure‐drop/pumping‐power model, with operating electricity assigned only to the cold‐side flow. Significant Findings Increasing length and diameter roughly doubles q and lifts T c ,out by up to ~6 K; adding tubes gives positive but diminishing returns as area gains offset lower per‐tube velocity. Shell‐side flow rate is the most effective operational lever, whereas raising can erode temperature lift—especially in small diameters—while increasing the cold‐side hydraulic penalty. Economic outcomes hinge on the displaced fuel: for electricity ($0.168 kWh −1 ), an n = 4, D i = 25.4 mm, L = 4 m design at T h ,in = 333 K delivers ~$8400 year −1 in savings, NPV ≈$47,700 and DPP ≈0.51 year; natural‐gas displacement ($0.050 kWh −1 ) remains attractive mainly for the largest geometries and high source temperatures, reaching NPV ≈$11,500 and DPP ≈1.77 year in the best case. Overall, within the idealised fully‐filled and steady‐state assumptions adopted here, MTHEs show potential as design candidates for building‐scale drain‐water heat recovery, particularly where electricity is the displaced fuel. However, experimental validation under realistic grey‐water hydrodynamics, fouling, intermittency and installation constraints remains necessary before practical performance can be confirmed.
Förderung
- Umm Al-Qura University
Zitieren
APA
Al-lehaibi, M., Rabih, A., Faraj, J., Achkar, G. E., Taher, R., Ali, S., & Khaled, M. (2026). Thermo‐Economic Assessment of Grey‐Water Heat Recovery Using Multi‐Tube Heat Exchangers. International Journal of Energy Research, 2026(1). https://doi.org/10.1155/er/8416976
Vancouver
Al-lehaibi M, Rabih A, Faraj J, Achkar GE, Taher R, Ali S, et al. Thermo‐Economic Assessment of Grey‐Water Heat Recovery Using Multi‐Tube Heat Exchangers. International Journal of Energy Research. 2026;2026(1). doi:10.1155/er/8416976
BibTeX
@article{Allehaibi2026,
author = {Al-lehaibi, Moaz and Rabih, Ali and Faraj, Jalal and Achkar, Georges El and Taher, Rani and Ali, Samer and Khaled, Mahmoud},
title = {Thermo‐Economic Assessment of Grey‐Water Heat Recovery Using Multi‐Tube Heat Exchangers},
journal = {International Journal of Energy Research},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/er/8416976}
}
EUVIMED