Thermodynamic and Techno‐Economic Comparison of Water‐Vapour Cascade and Liquid‐Injection Intercooled Heat Pumps for Industrial Heat at 200–350°C
International Journal of Energy Research · 2026-01 · 2026 (1)
DOI: 10.1155/er/4533207 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Energy Research, online erschienen am 28.09.2026. Verfasst von Amir Qatarani Nejad und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Water (R718) is a promising natural refrigerant for industrial high‐temperature heat pumps (HTHPs) because of its zero global warming potential (GWP), high critical temperature and favourable thermophysical properties. However, the wide saturation pressure span imposed by large temperature lifts produces demanding compressor pressure ratios and discharge temperatures that may exceed the operating range of steam compressors. This study presents an integrated thermodynamic and techno‐economic comparison of three water‐based pathways for high‐temperature industrial heat supply, namely a single‐stage cycle, multi‐stage compression with intercooling and multi‐cascade heat pumps. The study compares multi‐stage compression with intercooling and multi‐cascade heat pumps over evaporation temperatures of 75–150°C and condensation temperatures of 200–350°C, and links the thermodynamic results to capital cost, operating cost and levelised cost of heat (LCOH) in a 1 MW alumina‐refinery case study. For evaporation temperatures of 75–150°C and condensation temperatures of 200–350°C, the cascaded configuration gives the highest normalised coefficient of performance (COP norm ) under ideal heat exchange conditions. At practical pinch temperatures of 5–15 K, the relative advantage becomes condition dependent. Intercooled cycle is marginally favourable up to about 250°C, whereas the cascaded regains superiority at 300–350°C. At lower temperature lifts below about 125 K, intercooled cycle becomes increasingly competitive. In the case study, the cascaded configuration could achieve the highest COP of 1.68 and reduced the maximum compressor discharge temperature to 405.9°C, compared with 419.5°C for the intercooled configuration and 848.5°C for the single‐stage benchmark. The total project capital expenditure (CAPEX) values were 2.82, 3.28 and 3.37 million USD for the single stage, cascaded and intercooled configurations, respectively, with corresponding LCOH values of 123.2, 127.6 and 134.8 USD/MWh. These findings show that cascading same‐fluid R718 heat pumps can improve performance while mitigating compressor discharge temperature at high‐temperature lift applications.
Zitieren
APA
Nejad, A. Q., Yang, B., Hu, E., & Arjomandi, M. (2026). Thermodynamic and Techno‐Economic Comparison of Water‐Vapour Cascade and Liquid‐Injection Intercooled Heat Pumps for Industrial Heat at 200–350°C. International Journal of Energy Research, 2026(1). https://doi.org/10.1155/er/4533207
Vancouver
Nejad AQ, Yang B, Hu E, Arjomandi M. Thermodynamic and Techno‐Economic Comparison of Water‐Vapour Cascade and Liquid‐Injection Intercooled Heat Pumps for Industrial Heat at 200–350°C. International Journal of Energy Research. 2026;2026(1). doi:10.1155/er/4533207
BibTeX
@article{Nejad2026,
author = {Nejad, Amir Qatarani and Yang, Bo and Hu, Eric and Arjomandi, Maziar},
title = {Thermodynamic and Techno‐Economic Comparison of Water‐Vapour Cascade and Liquid‐Injection Intercooled Heat Pumps for Industrial Heat at 200–350°C},
journal = {International Journal of Energy Research},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/er/4533207}
}