EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Pulmonary Artery Thrombosis in a Growth Faltering Infant With Acinetobacter Sepsis—A Case Report

Allison T. Ong, Mariah Zakharia, Julia Green, Vikranth Raja, Natalia Jelen, Neha Veerabose, Juan Solano

Case Reports in Pediatrics · 2026-01 · 2026 (1)

DOI: 10.1155/crpe/1641981 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Case Reports in Pediatrics, online erschienen am 20.11.2026. Verfasst von Allison T. Ong und 6 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulmonary artery thrombosis is a rare finding in infant patients. Contributors to infant hypercoagulability include inherited thrombophilias, immature anticoagulation systems, and systemic insults such as septic shock and liver disease. Case Presentation We present the case of a 7‐week‐old girl with perinatal HIV exposure diagnosed with a pulmonary artery thrombus. The patient was admitted to the pediatric intensive care unit (PICU) for sepsis due to Acinetobacter nosocomialis bacteremia. During a workup for growth faltering and an S3 gallop, echocardiogram revealed a mass in the main pulmonary artery. Days later, after failing to achieve therapeutic anticoagulation, infant developed hypoxia and echocardiogram demonstrated worsening luminal obstruction by the thrombus, prompting urgent treatment with thrombectomy. We hypothesize that septic shock, with associated coagulopathy and severe dehydration, predisposed to thrombus formation in this critically ill patient.

Conclusions

This case highlights the rapid, multidisciplinary approach to diagnosing a pulmonary artery thrombus and the underlying factors contributing to hypercoagulability in an infant. This case is novel for the patient’s risk factor of perinatal HIV exposure, which may have predisposed her to opportunistic infection as well as thrombosis. Hypoxia and hemodynamic instability presented later in her course, prompting invasive management. Early recognition and timely intervention are essential for optimizing patient outcomes.

Zitieren

APA

Ong, A. T., Zakharia, M., Green, J., Raja, V., Jelen, N., Veerabose, N., & Solano, J. (2026). Pulmonary Artery Thrombosis in a Growth Faltering Infant With Acinetobacter Sepsis—A Case Report. Case Reports in Pediatrics, 2026(1). https://doi.org/10.1155/crpe/1641981

Vancouver

Ong AT, Zakharia M, Green J, Raja V, Jelen N, Veerabose N, et al. Pulmonary Artery Thrombosis in a Growth Faltering Infant With Acinetobacter Sepsis—A Case Report. Case Reports in Pediatrics. 2026;2026(1). doi:10.1155/crpe/1641981

BibTeX
@article{Ong2026,
  author = {Ong, Allison T. and Zakharia, Mariah and Green, Julia and Raja, Vikranth and Jelen, Natalia and Veerabose, Neha and Solano, Juan},
  title = {Pulmonary Artery Thrombosis in a Growth Faltering Infant With Acinetobacter Sepsis—A Case Report},
  journal = {Case Reports in Pediatrics},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/crpe/1641981}
}
Kostenlos starten →