EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of an In‐House Multiplex Real‐Time PCR Method With Altona Diagnostics Kits in the Detection of HSV, VZV, and EBV Viruses in Transplant Patients

Reyhaneh Kalhor iD, Mahdi Paryan iD, Sirous Naeimi iD, Hourieh Kalhor iD, Hassan Noorbazargan iD, Samira Mohammadi-Yeganeh iD

BioMed Research International · 2025

DOI: 10.1155/bmri/7109372 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift BioMed Research International, 2025. Verfasst von Reyhaneh Kalhor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Genetics, College of Science, Kazerun Branch, Islamic Azad University, Kazerun, Iran, azad.ac.ir. Hauptthemen laut MEDLINE: Herpesvirus 3, Human, Herpesvirus 4, Human, Real-Time Polymerase Chain Reaction, Simplexvirus. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Islamic Azad University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Herpes simplex virus (HSV), varicella‐zoster virus (VZV), and Epstein–Barr virus (EBV) infections pose significant challenges in managing transplant patients and necessitate rapid and precise diagnostic methods due to their immunosuppressed state. This study designed and evaluated the performance of an in‐house multiplex real‐time PCR for simultaneous detection of these viruses. Materials and Methods: Plasma samples from 270 transplant patients were tested using an in‐house multiplex real‐time PCR assay specifically designed for HSV, VZV, and EBV. Analytical specificity and the assay’s limit of detection (LOD) were determined. Statistical analyses were performed to evaluate the agreement between the in‐house assay and the reference kit.

Results

The method had a specificity of 98% for HSV, 97% for VZV, and 95% for EBV, alongside 100% sensitivity for all three viruses. No cross‐reactivity was observed with other viral or bacterial DNA. The LOD for the in‐house assay was determined to be 6.25, 25, and 25 copies/mL for HSV, VZV, and EBV, respectively. Additionally, precision analysis showed low CV values in both intra‐assay and interassay evaluations (HSV: 1.5%–1.8%; VZV: 2.3%–2.6%; and EBV: 3.7%–3.9%), confirming the assay’s robust analytical precision. Bland–Altman analysis showed mean differences of 1.35, −3.29, and 1.75 for HSV, VZV, and EBV, respectively. This multiplex real‐time PCR method enables detection at lower concentrations. Cross‐reactivity testing confirmed no interaction with DNA from other viruses or nontarget microorganisms. Bland–Altman and linear regression analyses also showed a strong agreement between commercial and in‐house methods.

Conclusion

These findings, compared to Altona diagnostic kits, highlight the value of designing and applying advanced diagnostic assays in managing viral infections in transplant patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Herpesvirus 3, HumanHerpesvirus 4, HumanReal-Time Polymerase Chain ReactionSimplexvirusMultiplex Polymerase Chain ReactionEpstein-Barr Virus InfectionsHerpes SimplexHumansFemaleMaleSensitivity and SpecificityReagent Kits, DiagnosticDNA, ViralAdultMiddle AgedLimit of Detection

Stichwörter der Autor:innen

EBVHSVVZVin-house assaymultiplex real-time PCRtransplant patients

Substanzen

Reagent Kits, DiagnosticDNA, Viral

Autor:innen und Institutionen

  • Department of Genetics, College of Science, Kazerun Branch, Islamic Azad University, Kazerun, Iran, azad.ac.ir.
  • Department of Research and Development, Production and Research Complex, Pasteur Institute of Iran, Tehran, Iran, pasteur.ac.ir.
  • Cellular and Molecular Research Center, Qom University of Medical Sciences, Qom, Iran, muq.ac.ir.
  • Roje Technologies Center, Tehran, Iran.
  • Medical Nanotechnology and Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir.
  • Department of Molecular Medicine, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran, sbmu.ac.ir.

ORCID-Profile: Reyhaneh Kalhor, Mahdi Paryan, Sirous Naeimi, Hourieh Kalhor, Hassan Noorbazargan, Samira Mohammadi-Yeganeh

Förderung

  • Islamic Azad University

Zitieren

APA

Kalhor, R., Paryan, M., Naeimi, S., Kalhor, H., Noorbazargan, H., & Mohammadi-Yeganeh, S. (2025). Comparison of an In‐House Multiplex Real‐Time PCR Method With Altona Diagnostics Kits in the Detection of HSV, VZV, and EBV Viruses in Transplant Patients. BioMed Research International. https://doi.org/10.1155/bmri/7109372

Vancouver

Kalhor R, Paryan M, Naeimi S, Kalhor H, Noorbazargan H, Mohammadi-Yeganeh S. Comparison of an In‐House Multiplex Real‐Time PCR Method With Altona Diagnostics Kits in the Detection of HSV, VZV, and EBV Viruses in Transplant Patients. BioMed Research International. 2025. doi:10.1155/bmri/7109372

BibTeX
@article{Kalhor2025,
  author = {Kalhor, Reyhaneh and Paryan, Mahdi and Naeimi, Sirous and Kalhor, Hourieh and Noorbazargan, Hassan and Mohammadi-Yeganeh, Samira},
  title = {Comparison of an In‐House Multiplex Real‐Time PCR Method With Altona Diagnostics Kits in the Detection of HSV, VZV, and EBV Viruses in Transplant Patients},
  journal = {BioMed Research International},
  year = {2025},
  doi = {10.1155/bmri/7109372}
}
Kostenlos starten →