Standardization of a Supramaximal Stimulation Protocol for Electrophysiological Assessment of the Intact Rat Median Nerve
BioMed Research International · 2026-01 · 2026 (1)
DOI: 10.1155/bmri/1960458 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift BioMed Research International, online erschienen am 17.04.2026. Verfasst von Tiago Bastos Taboada und 8 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Neurodegeneration and Repair, Department of Pathological Anatomy, Clementino Fraga Filho University Hospital, Federal University of Rio…. Hauptthemen laut MEDLINE: Median Nerve, Electric Stimulation, Action Potentials, Electromyography. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Introduction
Electroneuromyography (ENMG) is the gold‐standard method for assessing peripheral nerve function through compound muscle action potential (CMAP) amplitude and latency. However, methodological heterogeneity across studies limits reproducibility and comparability, particularly regarding stimulation intensity and electrode configuration.
Objective
This study is aimed at standardizing an ENMG protocol for the intact median nerve in rats by defining the minimal supramaximal stimulation intensity required to evoke maximal CMAP amplitude with stable latency.
Methods
A total of 10 adult male Wistar rats (250–300 g) were anesthetized with ketamine and xylazine. The right median nerve was surgically exposed at the brachial plexus level. A bipolar hook electrode delivered square‐wave pulses (0.1 ms, 1 Hz) at descending intensities (20–0.1 V), with a 60‐s interval between intensity blocks. CMAPs were recorded from the flexor digitorum superficialis using monopolar needle electrodes. Signals were amplified (10 Hz–10 kHz band‐pass) and digitized at 20 kHz. Amplitude and latency were analyzed across intensities to determine the supramaximal plateau.
Results
CMAP amplitude reached a plateau between 20 and 10 V, indicating full motor unit recruitment. Below 10 V, amplitude decreased progressively, and no response was observed at 0.1 V. Latency remained stable within the supramaximal range and increased only near threshold intensities.
Conclusion
This study establishes a standardized supramaximal stimulation parameter (10 V) for electrophysiological assessment of the intact rat median nerve. Defining this reference intensity enhances methodological consistency and supports reproducibility in experimental models of peripheral nerve research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Laboratory of Neurodegeneration and Repair, Department of Pathological Anatomy, Clementino Fraga Filho University Hospital, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil, ufrj.br.
- Graduate Program in Rehabilitation Sciences, School of Physiotherapy, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil, ufrj.br.
- Graduate Program in Pathological Anatomy, School of Medicine, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil, ufrj.br.
- Department of Anatomy, Dentistry School, Faculty of the Midwest Paulista (FACOP), Piratininga, São Paulo, Brazil.
- Institute of Biomedical Sciences, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil, ufrj.br.
ORCID-Profile: Ana Maria Blanco Martinez
Förderung
- Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Taboada, T. B., Pestana, F. M., Oliveira, J. T., Junior, G. M. R., Mendonça, H. R., da Silva, B. T., de Campos, N. T., de Almeida, F. M., & Martinez, A. M. B. (2026). Standardization of a Supramaximal Stimulation Protocol for Electrophysiological Assessment of the Intact Rat Median Nerve. BioMed Research International, 2026(1). https://doi.org/10.1155/bmri/1960458
Vancouver
Taboada TB, Pestana FM, Oliveira JT, Junior GMR, Mendonça HR, da Silva BT, et al. Standardization of a Supramaximal Stimulation Protocol for Electrophysiological Assessment of the Intact Rat Median Nerve. BioMed Research International. 2026;2026(1). doi:10.1155/bmri/1960458
BibTeX
@article{Taboada2026,
author = {Taboada, Tiago Bastos and Pestana, Fernanda Marques and Oliveira, Julia Teixeira and Junior, Geraldo Marco Rosa and Mendonça, Henrique Rocha and da Silva, Beatriz Theodoro and de Campos, Natália Tavares and de Almeida, Fernanda Martins and Martinez, Ana Maria Blanco},
title = {Standardization of a Supramaximal Stimulation Protocol for Electrophysiological Assessment of the Intact Rat Median Nerve},
journal = {BioMed Research International},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/bmri/1960458}
}
EUVIMED