Fachartikel in der Zeitschrift Advances in Urology, online erschienen am 13.08.2026. Verfasst von Oleksandr Chepeliuk und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Sheba Medical Center, Ramat Gan, Israel, sheba.co.il. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To compare Holmium: YAG laser settings for popcorn lithotripsy and evaluate the impact of MOSES modulation across stone‐density groups. Materials and Methods An in vitro bench model was used with synthetic gypsum stones prepared at three density levels (low, intermediate, and high: mean attenuation was 574, 945, and 2067 HU, respectively). For each trial, five fragments (2.8–3.3 mm) were treated using popcorn technique with Holmium: YAG laser and 272 µm fiber during a 2 min run under standardized irrigation. Five laser settings (0.3 J/80 Hz, 0.5 J/40 Hz, 1.0 J/20 Hz, 1.0 J/30 Hz, and 1.5 J/20 Hz) were tested with and without MOSES mode: each setting‐by‐modulation condition was repeated six times. The primary endpoint was percent mass reduction; secondary endpoints were residual fragment counts 1–2 and > 2 mm. Results are presented as mean ± SD, and ANOVA was used for comparison.
Results
In the low‐density group, percent mass reduction was highest overall (65%–86%), with 1.0 J/30 Hz achieving the greatest reduction, MOSES provided no additional benefit ( p = 0.6). In the intermediate‐density group, the greatest mass reduction was achieved with 1.0 J/30 Hz with MOSES (51% ± 5.9%), and MOSES effects were setting‐dependent, and at 1.0 J/30 Hz MOSES reduced total residual fragments (5.3 vs 8.0, p = 0.04). In the high‐density group, 1.0 J/30 Hz with MOSES achieved the highest mass reduction (71.5% ± 12.1%) and was associated with improved outcomes ( p = 0.037). Secondary analyses of residual fragments generally paralleled these findings.
Conclusions
In this in vitro popcorn lithotripsy model, 1.0 J/30 Hz provided the most consistent performance across density groups. MOSES modulation did not improve outcomes in low‐density stones but was associated with improved efficiency in intermediate‐ and high‐density stones.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Sheba Medical Center, Ramat Gan, Israel, sheba.co.il.
- Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv, Israel, tau.ac.il.
- Operative Room Division, Anesthesia and Pain, Sheba Medical Center, Ramat Gan, Israel, sheba.co.il.
ORCID-Profile: Oleksandr Chepeliuk, Asaf Shvero, Rinat Lasmanovich, A Zohar Dotan, E Dorit Zilberman
Zitieren
APA
Chepeliuk, O., Shvero, A., Lasmanovich, R., Caballero, L. I., Orkin, D., Dotan, A. Z., Zilberman, E. D., & Kleinmann, N. (2026). Holmium: YAG Popcorn Lithotripsy—In Vitro Comparison of Settings and MOSES Across Stone Densities. Advances in Urology, 2026(1). https://doi.org/10.1155/aiu/3584394
Vancouver
Chepeliuk O, Shvero A, Lasmanovich R, Caballero LI, Orkin D, Dotan AZ, et al. Holmium: YAG Popcorn Lithotripsy—In Vitro Comparison of Settings and MOSES Across Stone Densities. Advances in Urology. 2026;2026(1). doi:10.1155/aiu/3584394
BibTeX
@article{Chepeliuk2026,
author = {Chepeliuk, Oleksandr and Shvero, Asaf and Lasmanovich, Rinat and Caballero, Lopez Isaias and Orkin, Dina and Dotan, A Zohar and Zilberman, E Dorit and Kleinmann, Nir},
title = {Holmium: YAG Popcorn Lithotripsy—In Vitro Comparison of Settings and MOSES Across Stone Densities},
journal = {Advances in Urology},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/aiu/3584394}
}
EUVIMED