Improving the Behavior of Cold Mix Asphalt With Induction Heating After Asphalt Paving
Advances in Civil Engineering · 2026-01 · 2026 (1)
DOI: 10.1155/adce/8220552 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advances in Civil Engineering, online erschienen am 23.07.2026. Verfasst von S. M. Mirabdolazimi und 4 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Cold asphalt exhibits weaker mechanical properties (stiffness, deformation, and fatigue, etc.) and moisture resistance compared to hot mix asphalt (HMA). Its high moisture sensitivity is due to its low‐temperature production, which manifests as poor adhesion between bitumen and aggregates. Due to this high moisture sensitivity, cold asphalt is not suitable for high‐traffic roads. This research aims to find a method to mitigate the shortcomings of cold asphalt. In this study, after adding an inductive agent (iron powder) to the cold asphalt mixture, the effect of postconstruction induction heating on fracture mechanisms, moisture sensitivity, freeze–thaw durability, fatigue, and thermal sensitivity of the mixture was evaluated. To determine the fracture mechanism of cold asphalt, the semicircular bending (SCB) test was used. Also, the evaluation of moisture and thermal sensitivity, freeze–thaw durability, and fatigue of the mixture was based on the results of the indirect tensile strength (ITS) test. The results showed that the use of induction heating in the cold asphalt mixture, at both curing times of 7 and 21 days, compared to the cold asphalt mixture without induction heating, increased moisture resistance and fracture resistance. Furthermore, under freeze–thaw cycles, the durability of the mixtures after induction heating increased, and the weight loss decreased. Additionally, after 7 days of curing, the induced samples showed 6%–27% higher fatigue resistance compared to the noninduced samples. This increase improved by up to 78% after 21 days of curing. Similarly, in the indirect tensile cracking test, the cracking resistance of the samples improved by 107% at 7 days of curing and 50% at 21 days of curing.
Zitieren
APA
Mirabdolazimi, S. M., Sadeghnejad, M., Zohdi, M. S., Rouzafrouzi, M., & Navidi, T. (2026). Improving the Behavior of Cold Mix Asphalt With Induction Heating After Asphalt Paving. Advances in Civil Engineering, 2026(1). https://doi.org/10.1155/adce/8220552
Vancouver
Mirabdolazimi SM, Sadeghnejad M, Zohdi MS, Rouzafrouzi M, Navidi T. Improving the Behavior of Cold Mix Asphalt With Induction Heating After Asphalt Paving. Advances in Civil Engineering. 2026;2026(1). doi:10.1155/adce/8220552
BibTeX
@article{Mirabdolazimi2026,
author = {Mirabdolazimi, S. M. and Sadeghnejad, M. and Zohdi, M. S. and Rouzafrouzi, M. and Navidi, T.},
title = {Improving the Behavior of Cold Mix Asphalt With Induction Heating After Asphalt Paving},
journal = {Advances in Civil Engineering},
year = {2026},
volume = {2026},
number = {1},
doi = {10.1155/adce/8220552}
}
EUVIMED