EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of Recycled Brick Aggregate Concrete Reinforced With Hybrid Rubber and Polypropylene Fibers Under Mechanical, Impact, and Elevated‐Temperature Loading

Md Jahidul Islam, Mahir Asiful Haque, Mansura Oyshi, Nafisa Tanjim Raisa

Advances in Civil Engineering · 2026-01 · 2026 (1)

DOI: 10.1155/adce/1891652 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Civil Engineering, online erschienen am 02.08.2026. Verfasst von Md Jahidul Islam und 3 weiteren Autor:innen. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recycled brick aggregate (RBA) offers a practical route to reduce natural aggregate consumption, but its impact and elevated‐temperature performance remain unclear when combined with hybrid fibers. This study evaluates whether rubber fiber (RF) and polypropylene fiber (PPF) can improve the impact resistance (IR) and residual compressive strength (CS) of RBA concrete. Ten mixtures were prepared using RF at 0%, 5%, and 10% replacement of fine aggregate (FA) by volume and PPF at 0%, 0.2%, and 0.4% of cement mass. The mixtures were tested for CS, splitting tensile strength (STS), flexural strength (FS), modulus of elasticity (MoE), surface absorption (SA), surface resistivity (SR), ultrasonic pulse velocity (UPV), drop‐weight IR, and residual CS after exposure to 400 and 600°C. Scanning electron microscopy (SEM) and energy‐dispersive spectroscopy (EDS) were used to interpret the microstructural response. The mix containing 0.4% PPF and 10% RF showed the highest IR, with a 168% increase relative to the RBA control. After exposure to 600°C, selected fiber‐modified mixes showed 7%–73% higher residual CS than the heated RBA control. This residual‐strength improvement was mainly attributed to matrix‐level changes, pore‐structure modification, and the ceramic nature of RBA, rather than intact fiber action at 600°C. SEM and EDS supported the discussion by showing changes in void size, interfacial features, and silicon‐rich regions after heating. These results indicate that hybrid RF–PPF RBA concrete can improve IR while maintaining acceptable residual performance under selected elevated‐temperature conditions.

Zitieren

APA

Islam, M. J., Haque, M. A., Oyshi, M., & Raisa, N. T. (2026). Performance of Recycled Brick Aggregate Concrete Reinforced With Hybrid Rubber and Polypropylene Fibers Under Mechanical, Impact, and Elevated‐Temperature Loading. Advances in Civil Engineering, 2026(1). https://doi.org/10.1155/adce/1891652

Vancouver

Islam MJ, Haque MA, Oyshi M, Raisa NT. Performance of Recycled Brick Aggregate Concrete Reinforced With Hybrid Rubber and Polypropylene Fibers Under Mechanical, Impact, and Elevated‐Temperature Loading. Advances in Civil Engineering. 2026;2026(1). doi:10.1155/adce/1891652

BibTeX
@article{Islam2026,
  author = {Islam, Md Jahidul and Haque, Mahir Asiful and Oyshi, Mansura and Raisa, Nafisa Tanjim},
  title = {Performance of Recycled Brick Aggregate Concrete Reinforced With Hybrid Rubber and Polypropylene Fibers Under Mechanical, Impact, and Elevated‐Temperature Loading},
  journal = {Advances in Civil Engineering},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/adce/1891652}
}
Kostenlos starten →