EUVIMEDEUVIMED entdecken
ValidierungsstudieBeobachtungsstudieMultizentrische StudieOpen Access · CC BY 4.0

Development, Validation, and Diagnostic Accuracy of the Fetal Lack of Responsiveness Scale for Diagnosis of Severe Perinatal Hypoxia

Luis Carlos Franco iD, Sandra M Buitrago iD, Isabel Arbelaez iD, Laura F Pinto iD, Daniela Blanco iD, María C Pizarro iD, Laura Santamaria iD, Catalina Trillos iD

Journal of Pregnancy · 2024

DOI: 10.1155/2024/9779831 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Pregnancy, 2024. Verfasst von Luis Carlos Franco und 7 weiteren Autor:innen. Beteiligte Einrichtung: Facultad de medicina, Universidad de Los Andes, Bogotá, Colombia. Hauptthemen laut MEDLINE: Fetal Hypoxia, Cardiotocography. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

There are limitations to predicting perinatal asphyxia, as current tools rely almost entirely on fetal cardiotocography (CTG). The fetal lack of responsiveness scale (FLORS) is a new diagnostic alternative based on the physiological phenomena associated with fetal hypoxia.

Objectives

The objective of this study was to develop, validate, and assess the diagnostic accuracy of the FLORS for predicting severe perinatal hypoxia (SPH). Study Design: A two‐phase retrospective observational cross‐sectional analytical study was conducted. Phase 1 involved the formulation and retrospective validation of the FLORS. A total of 366 fetal CTG records were evaluated twice by seven readers. Phase 2 was a collaborative, retrospective, multicenter diagnostic test study that included 37 SPH and 366 non‐SPH cases.

Results

Phase 1: A numeric, physiology‐based scale was developed and refined based on expert opinions. The median time to apply the scale per reading was 38 s. Cronbach’s alpha, which is a reliability measure, was significant ( p = 0.784). The kappa index for test–retest agreement was moderate to reasonable, with a median value of 0.642. For interobserver agreement, the kappa index per variable was as follows: baseline, 0.669; accelerations, 0.658; variability, 0.467; late/variable decelerations, 0.638; slow response decelerations, 0.617; and trend to change, 0.423. Phase 2, including 37 SPH and 366 non‐SPH cases, showed a sensitivity of 62.2% and specificity of 75.4% for the 2‐point score, whereas the 3‐point score had a sensitivity of 35.1% and specificity of 89.9%. The area under the curve (AUC) was significant at 0.73 (CI 0.645–0.818).

Conclusions

FLORS demonstrated significant internal consistency and observer agreement, with a promising sensitivity–specificity balance and significant AUC. Further research is needed to assess its impact on perinatal hypoxia and cesarean delivery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fetal HypoxiaCardiotocographyHumansFemaleCross-Sectional StudiesPregnancyRetrospective StudiesReproducibility of ResultsAsphyxia NeonatorumSensitivity and SpecificityInfant, NewbornHeart Rate, FetalAdult

Autor:innen und Institutionen

  • Facultad de medicina, Universidad de Los Andes, Bogotá, Colombia.
  • Hospital universitario Fundación Santa Fé de Bogotá, Grupo de investigación en ginecología obstetricia y reproducción humana, Bogotá, Colombia.
  • Sub Red Centro Oriente, Hospital Materno Infantil, Bogotá, Colombia.

ORCID-Profile: Luis Carlos Franco, Sandra M Buitrago, Isabel Arbelaez, Laura F Pinto, Daniela Blanco, María C Pizarro, Laura Santamaria, Catalina Trillos

Zitieren

APA

Franco, L. C., Buitrago, S. M., Arbelaez, I., Pinto, L. F., Blanco, D., Pizarro, M. C., Santamaria, L., & Trillos, C. (2024). Development, Validation, and Diagnostic Accuracy of the Fetal Lack of Responsiveness Scale for Diagnosis of Severe Perinatal Hypoxia. Journal of Pregnancy. https://doi.org/10.1155/2024/9779831

Vancouver

Franco LC, Buitrago SM, Arbelaez I, Pinto LF, Blanco D, Pizarro MC, et al. Development, Validation, and Diagnostic Accuracy of the Fetal Lack of Responsiveness Scale for Diagnosis of Severe Perinatal Hypoxia. Journal of Pregnancy. 2024. doi:10.1155/2024/9779831

BibTeX
@article{Franco2024,
  author = {Franco, Luis Carlos and Buitrago, Sandra M and Arbelaez, Isabel and Pinto, Laura F and Blanco, Daniela and Pizarro, María C and Santamaria, Laura and Trillos, Catalina},
  title = {Development, Validation, and Diagnostic Accuracy of the Fetal Lack of Responsiveness Scale for Diagnosis of Severe Perinatal Hypoxia},
  journal = {Journal of Pregnancy},
  year = {2024},
  doi = {10.1155/2024/9779831}
}
Kostenlos starten →