EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

CFD Simulation and ANN Prediction of Hydrogen Leakage and Diffusion Behavior in a Hydrogen Refuelling Station

Jinsheng Xiao, Nianfeng Xu, Yaze Li, Guodong Li, Min Liu, Liang Tong, Chengqing Yuan, Xuefang Li, Tianqi Yang

International Journal of Energy Research · 2024-01 · 2024 (1)

DOI: 10.1155/2024/8910533 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Energy Research, online erschienen am 15.07.2024. Verfasst von Jinsheng Xiao und 8 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Zhejiang Electric Power Company, National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydrogen refueling station (HRS) is an essential part of the infrastructure for promoting the hydrogen economy. Since hydrogen is a flammable and explosive gas, hydrogen released from high‐pressure hydrogen storage equipment in HRS will likely cause combustion or explosion accidents. Studying high‐pressure hydrogen leakage in HRS is a prerequisite for promoting hydrogen fuel cell vehicles and HRS. A computational fluid dynamics (CFD) model of an HRS in a demonstrated project in Ningbo, China, was established on the ANSYS FLUENT software platform. The CFD model for hydrogen leakage simulation was validated by comparing the simulation results with experimental data in the literature. The effects of the direction and mass flow rate of the hydrogen leakage jet, as well as the direction and speed of ambient wind, on hydrogen diffusion behavior were investigated. The spreading distances of the flammable hydrogen cloud were predicted using an artificial neural network for horizontal leakage. The results show that the jet direction strongly affected the flammable cloud flow. The greater the mass flow rate of the leak, the greater the hydrogen dispersion distance and the volume of the flammable hydrogen cloud. At a hydrogen leakage mass flow rate of 4.5589 kg/s, the volume of the hydrogen flammable cloud reached 6,140.46 m 3 at 30 s of leakage. The ambient wind speed has complicated effects on spreading the flammable cloud. The wind makes the flammable cloud move in certain directions, and the higher wind speed accelerates the diffusion of the flammable gas in the air. The results of the study can be used as a reference for the study of high‐pressure hydrogen leakage in HRS and will play an important role in the safe demonstration of the studied project.

Förderung

  • State Grid Zhejiang Electric Power Company
  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Hubei Province
  • Ministry of Education of the People's Republic of China

Zitieren

APA

Xiao, J., Xu, N., Li, Y., Li, G., Liu, M., Tong, L., Yuan, C., Li, X., & Yang, T. (2024). CFD Simulation and ANN Prediction of Hydrogen Leakage and Diffusion Behavior in a Hydrogen Refuelling Station. International Journal of Energy Research, 2024(1). https://doi.org/10.1155/2024/8910533

Vancouver

Xiao J, Xu N, Li Y, Li G, Liu M, Tong L, et al. CFD Simulation and ANN Prediction of Hydrogen Leakage and Diffusion Behavior in a Hydrogen Refuelling Station. International Journal of Energy Research. 2024;2024(1). doi:10.1155/2024/8910533

BibTeX
@article{Xiao2024,
  author = {Xiao, Jinsheng and Xu, Nianfeng and Li, Yaze and Li, Guodong and Liu, Min and Tong, Liang and Yuan, Chengqing and Li, Xuefang and Yang, Tianqi},
  title = {CFD Simulation and ANN Prediction of Hydrogen Leakage and Diffusion Behavior in a Hydrogen Refuelling Station},
  journal = {International Journal of Energy Research},
  year = {2024},
  volume = {2024},
  number = {1},
  doi = {10.1155/2024/8910533}
}
Kostenlos starten →