Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation
Journal of Ophthalmology · 2023-01 · 2023 (1)
DOI: 10.1155/2023/7680659 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ophthalmology, online erschienen am 07.07.2023. Verfasst von Ruxin Gao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Eye Institute & Affiliated Xiamen Eye Center, School of Medicine, Xiamen University, Xiamen 361001, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Fujian Province, Medical Innovation Project of Fujian Province.
Abstract (Originalsprache)
Objective
To evaluate the influence of pilocarpine eyedrops on the ocular biometric parameters and whether these parameter changes affect the intraocular lens (IOL) power calculation in patients with primary angle‐closure glaucoma (PACG).
Methods
Twenty‐two PACG patients and fifteen normal subjects were enrolled. Ocular biometric parameters including the axial length (AL), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), and white‐to‐white distance (WTW) were measured by using a Lenstar LS 900 device before and at least 30 minutes after instillation of 2% pilocarpine eyedrops. Lens position (LP) was calculated, and the IOL power prediction based on the ocular biometric parameters was performed using the Barrett Universal II, Haigis, Hoffer Q, Holladay I, or SRK/T formulas before and after pilocarpine application.
Results
In both PACG and normal groups, pilocarpine eyedrops induced a slight but statistically significant increase in the mean AL (0.01 mm for both groups) and mean LT (0.02 mm and 0.03 mm, respectively) but a significant decrease in the mean ACD (0.03 mm and 0.05 mm, respectively) and mean LP (0.02 mm and 0.04 mm, respectively). No significant changes in the mean Km and WTW were noticed in both groups. In addition, the IOL power calculation revealed insignificant changes before and after the pilocarpine instillation in both groups, regardless of the formula used.
Conclusions
Pilocarpine eyedrops can induce slight changes in the ocular biometric parameters including the AL, ACD, LT, and LP. However, these parameter changes will not result in a significant difference in IOL power estimation.
Autor:innen und Institutionen
- Department of Ophthalmology, Eye Institute & Affiliated Xiamen Eye Center, School of Medicine, Xiamen University, Xiamen 361001, China.
- Department of Ophthalmology, Fujian Provincial Key Laboratory of Corneal & Ocular Surface Diseases, Xiamen 361001, China.
ORCID-Profile: Ruxin Gao, Jinkun Liu, Xiaojie Zhou, Luping Huang, Weiyi Huang, Yingying Xue, Fei Wang, Songjian Gong, Renyi Wu, Yuhong Wang
Förderung
- Natural Science Foundation of Fujian Province
- Medical Innovation Project of Fujian Province
Zitieren
APA
Gao, R., Liu, J., Zhou, X., Huang, L., Huang, W., Xue, Y., Wang, F., Gong, S., Wu, R., & Wang, Y. (2023). Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation. Journal of Ophthalmology, 2023(1). https://doi.org/10.1155/2023/7680659
Vancouver
Gao R, Liu J, Zhou X, Huang L, Huang W, Xue Y, et al. Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation. Journal of Ophthalmology. 2023;2023(1). doi:10.1155/2023/7680659
BibTeX
@article{Gao2023,
author = {Gao, Ruxin and Liu, Jinkun and Zhou, Xiaojie and Huang, Luping and Huang, Weiyi and Xue, Yingying and Wang, Fei and Gong, Songjian and Wu, Renyi and Wang, Yuhong},
title = {Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation},
journal = {Journal of Ophthalmology},
year = {2023},
volume = {2023},
number = {1},
doi = {10.1155/2023/7680659}
}
EUVIMED