EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hazards and Treatment of Collapsible Loess Foundation on Ultrahigh Voltage Transmission Lines

Longfei Zhang, Zaiqiang Hu, Hongru Li, Haicheng She, Xiaoliang Wang, Xiaoning Han, Xi Yang

Advances in Civil Engineering · 30.06.2023 · 2023 · 1-18

DOI: 10.1155/2023/7272036 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Civil Engineering, erschienen am 30.06.2023. Verfasst von Longfei Zhang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, The Science and Technology Innovation Project of Key Laboratory of Shaanxi Province China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the development of ultrahigh voltage transmission line construction in northwest China, an increasing number of overhead transmission lines are crossing the loess regions. Ensuring the stability of electricity transmission towers and mitigating the risk of collapse are crucial prerequisites for the construction of transmission lines. Taking the 750 kV demonstration electricity transmission line in Guanting–Lanzhou East as an example, representative loess samples were selected for compression and collapsing sensitivity tests. Four foundation treatment schemes were designed, and the wetting deformation characteristics were investigated through numerical simulation of the rainfall infiltration process. Corresponding optimisation schemes were proposed. The collapsing process was divided into four stages through laboratory collapsing tests. The relationship function between saturation and the Duncan–Chang model parameters of loess was established, which was introduced into the finite element model to consider the rainfall infiltration process. The analysis of the displacement field, and loess saturation field with time after rainfall infiltration for the four schemes showed that adding a lime-stabilised soil cushion layer and waterproof layer to the inclined column foundation had the best effect. Given that the design scheme needs to consider safety and economy, the thickness of the cushion layer was optimised, thereby reducing the use of lime-stabilised soil by 20%. Research findings provide meaningful guidance for the design of transmission tower foundations in loess areas.

Förderung

  • National Natural Science Foundation of China
  • The Science and Technology Innovation Project of Key Laboratory of Shaanxi Province China

Zitieren

APA

Zhang, L., Hu, Z., Li, H., She, H., Wang, X., Han, X., & Yang, X. (2023). Hazards and Treatment of Collapsible Loess Foundation on Ultrahigh Voltage Transmission Lines. Advances in Civil Engineering, 2023, 1-18. https://doi.org/10.1155/2023/7272036

Vancouver

Zhang L, Hu Z, Li H, She H, Wang X, Han X, et al. Hazards and Treatment of Collapsible Loess Foundation on Ultrahigh Voltage Transmission Lines. Advances in Civil Engineering. 2023;2023:1-18. doi:10.1155/2023/7272036

BibTeX
@article{Zhang2023,
  author = {Zhang, Longfei and Hu, Zaiqiang and Li, Hongru and She, Haicheng and Wang, Xiaoliang and Han, Xiaoning and Yang, Xi},
  title = {Hazards and Treatment of Collapsible Loess Foundation on Ultrahigh Voltage Transmission Lines},
  journal = {Advances in Civil Engineering},
  year = {2023},
  volume = {2023},
  pages = {1--18},
  doi = {10.1155/2023/7272036}
}
Kostenlos starten →