Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring
International Journal of Clinical Practice · 2023
DOI: 10.1155/2023/6530295 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Clinical Practice, 2023. Verfasst von Alena Havelkova und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, Faculty of Medicine, Masaryk University, Brno, Czech Republic. Hauptthemen laut MEDLINE: Coronary Artery Disease, Cardiovascular Diseases, Hypertension. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Czech Clinical Research Infrastructure Network CZECRIN.
Abstract (Originalsprache)
Aim
Specify the risk rate of incorrect patient classification based on the night-to-day ratio specification from singular 24-h ABPM in comparison to the results of 7-day ABPM monitoring Materials and Methods. 1197 24 h cycles were enrolled in 171 subjects in the study and divided into 4 groups: group 1 (40 healthy men and women without exercise), group 2 (40 healthy exercise-training men and women), group 3 (40 patients with ischemic coronary artery disease without exercise), and group 4 (51 patients with ischemic coronary artery disease following cardiovascular rehabilitation). The subject of the evaluation was the percentage rate of incorrect subject classification (dipper, nondipper, extreme dipper, and riser) based on the mean blood pressure values for 7 days and from seven independent 24-hour cycles (the mean value mode).
Results
In the case of the individuals included in the monitored groups, the mean night-to-day ratio-based (mode for the 7 days versus the individual days of 24-hour monitoring) classification accordance ranged between 59% and 62%. Only in singular cases did the accordance reach 0% or 100%. The accordance size was not dependent on the health or cardiovascular disease ( p < 0.594 ; 56% vs. 54%) or physical activity ( p < 0.833 ; 55% vs. 54%) of the monitored individuals.
Conclusion
The specification of the night-to-day ratio of each individual for each day of the 7-day ABPM monitoring would be the most convenient option. In many patients, diagnosing could thus be based on the most frequently occurring values (mode specification). The study protocol was registered with ClinicalTrials.gov (NCT05264090)
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physiotherapy, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- St. Anne's Teaching Hospital, Brno, Czech Republic.
- Department of Biology, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences, Brno, Czech Republic.
- Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN, USA.
ORCID-Profile: Alena Havelkova
Förderung
- Czech Clinical Research Infrastructure Network CZECRIN
Zitieren
APA
Havelkova, A., Dvorak, P., Siegelova, J., Dobsak, P., Filipensky, P., & Cornelissen, G. (2023). Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring. International Journal of Clinical Practice. https://doi.org/10.1155/2023/6530295
Vancouver
Havelkova A, Dvorak P, Siegelova J, Dobsak P, Filipensky P, Cornelissen G. Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring. International Journal of Clinical Practice. 2023. doi:10.1155/2023/6530295
BibTeX
@article{Havelkova2023,
author = {Havelkova, Alena and Dvorak, Petr and Siegelova, Jarmila and Dobsak, Petr and Filipensky, Petr and Cornelissen, Germaine},
title = {Possibilities of Interpreting the Night-to-Day Ratio Specified by 24-Hour Blood Pressure Monitoring},
journal = {International Journal of Clinical Practice},
year = {2023},
doi = {10.1155/2023/6530295}
}