Nonintrusive Sensor System Developed Using a Force-Sensing Resistor for Pipeline Integrity Monitoring
Structural Control and Health Monitoring · 07.02.2023 · 2023 · 1-14
DOI: 10.1155/2023/4676060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Structural Control and Health Monitoring, erschienen am 07.02.2023. Verfasst von Jin-woo Park und 4 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Institute of Machinery and Materials, Ministry of Trade, Industry and Energy, National Research Foundation of Korea.
Abstract (Originalsprache)
Pipelines are crucial for transporting liquid and gaseous resources at various industrial sites. As unexpected pipeline failures and improper spill responses often cause detrimental effects on the environment and public safety, real-time leakage monitoring and detection are important. This study proposes a nonintrusive sensor system to measure the pressure and integrity of a pipeline in real time by easily installing nonintrusive sensors on the exterior of the pipelines. Initially, a prototype of the nonintrusive pressure-monitoring sensor was designed and fabricated. This sensor correlated the changes in pressure inside a pipe with those in the contact force exerted between the pipe and the surrounding high-stiffness band; a force-sensing resistor was used to measure the contact force. Furthermore, parametric studies were performed on a six-inch pipe, which indicated that the developed sensor can accurately monitor the inner pressure of the pipe. We also developed a methodology to determine the optimal sensor placement in a pipeline network for detecting damages using the Euclidean distance method. This was combined with the methodology of determining the decision boundary for classifying the damage location using a support vector machine to rapidly detect the damage using a minimum number of sensors. Finally, a nonintrusive sensor system was installed on the fire main pipeline system, and the damage detection performance was experimentally validated. The developed nonintrusive sensor system can be easily installed on operating pipes to monitor the inner pressure of a pipe in real-time and accurately detect damages in a pipeline network.
Förderung
- Korea Institute of Machinery and Materials
- Ministry of Trade, Industry and Energy
- National Research Foundation of Korea
Zitieren
APA
Park, J., Jung, B. C., Lee, S. H., Huh, Y. C., & Shin, Y. (2023). Nonintrusive Sensor System Developed Using a Force-Sensing Resistor for Pipeline Integrity Monitoring. Structural Control and Health Monitoring, 2023, 1-14. https://doi.org/10.1155/2023/4676060
Vancouver
Park J, Jung BC, Lee SH, Huh YC, Shin Y. Nonintrusive Sensor System Developed Using a Force-Sensing Resistor for Pipeline Integrity Monitoring. Structural Control and Health Monitoring. 2023;2023:1-14. doi:10.1155/2023/4676060
BibTeX
@article{Park2023,
author = {Park, Jin-woo and Jung, Byung Chang and Lee, Sang Hyuk and Huh, Young Cheol and Shin, Yun-ho},
title = {Nonintrusive Sensor System Developed Using a Force-Sensing Resistor for Pipeline Integrity Monitoring},
journal = {Structural Control and Health Monitoring},
year = {2023},
volume = {2023},
pages = {1--14},
doi = {10.1155/2023/4676060}
}
EUVIMED