Optimization of the Coupling Coefficient of the Inductive Link for Wireless Power Transfer to Biomedical Implants

Jiarui Bao, Shuyan Hu, Zibin Xie, Guangxi Hu, Ye Lu, Lirong Zheng

International Journal of Antennas and Propagation · 06.01.2022 · 2022 · 1-12

DOI: 10.1155/2022/8619514 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Antennas and Propagation, erschienen am 06.01.2022. Verfasst von Jiarui Bao und 5 weiteren Autor:innen. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Postdoctoral Science Foundation, National Natural Science Foundation of China, Shanghai Pujiang Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work focuses on the optimization of coupling coefficient (k) of the inductive link for the wireless power transfer (WPT) system to be used in implantable medical devices (IMDs) of centimeter size. The analytic expression of k is presented. Simulations are conducted by using the high-frequency structure simulator (HFSS). Analytic results are verified with simulations. The receiving (Rx) coil is implanted in the body and set as a circular coil with a radius of 5 millimeters for reducing the risk of tissue inflammation. The inductive link under misalignment scenarios is optimized to improve k. When the distance between the transmitting (Tx) and Rx coils is fixed at 20 mm, it is found that, to maximize k, the Tx coil in a planar spiral configuration with an average radius of 20 mm is preferred, and the Rx coil in a solenoid configuration with a wire pitch of 0.7 mm is recommended. Based on these optimization results, an inductive link WPT system is proposed; the coupling coefficient k, the power transfer efficiency (PTE), and the maximum power delivered to the load (MPDL) of the system are obtained with both simulation and experiment. Different media of air, muscle, and bone separating the Tx and Rx coils are tested. For the muscle (bone) medium, PTE is 44.14% (43.07%) and MPDL is 145.38 mW (128.13 mW), respectively.

Förderung

  • China Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Shanghai Pujiang Program

Zitieren

APA

Bao, J., Hu, S., Xie, Z., Hu, G., Lu, Y., & Zheng, L. (2022). Optimization of the Coupling Coefficient of the Inductive Link for Wireless Power Transfer to Biomedical Implants. International Journal of Antennas and Propagation, 2022, 1-12. https://doi.org/10.1155/2022/8619514

Vancouver

Bao J, Hu S, Xie Z, Hu G, Lu Y, Zheng L. Optimization of the Coupling Coefficient of the Inductive Link for Wireless Power Transfer to Biomedical Implants. International Journal of Antennas and Propagation. 2022;2022:1-12. doi:10.1155/2022/8619514

BibTeX
@article{Bao2022,
  author = {Bao, Jiarui and Hu, Shuyan and Xie, Zibin and Hu, Guangxi and Lu, Ye and Zheng, Lirong},
  title = {Optimization of the Coupling Coefficient of the Inductive Link for Wireless Power Transfer to Biomedical Implants},
  journal = {International Journal of Antennas and Propagation},
  year = {2022},
  volume = {2022},
  pages = {1--12},
  doi = {10.1155/2022/8619514}
}
Kostenlos starten →