Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
Journal of Interventional Cardiology · 26.03.2022 · 2022 · 1-6
DOI: 10.1155/2022/5692964 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Interventional Cardiology, erschienen am 26.03.2022. Verfasst von Nour Tashtish und 9 weiteren Autor:innen. Beteiligte Einrichtung: Harrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, USA. Hauptthemen laut MEDLINE: Coronary Thrombosis, Myocardial Infarction, Percutaneous Coronary Intervention, Stroke. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Evaluation of the safety and efficacy of the Penumbra device as an adjunct to percutaneous coronary intervention (PCI) in patients with myocardial infarction (MI) and a large thrombus burden that requires thrombectomy.
Background
For patients with acute MI, PCI is the primary reperfusion method. Large thrombus burden has always been a limitation of successful reperfusion. However, the use of current aspiration devices has been associated with an increased incidence of stroke.
Methods
We performed a retrospective chart review at the University Hospitals Medical Center in Cleveland. Our study included data from patients who underwent PCI for ST segment elevation myocardial infarction (STEMI) and non-ST segment elevation myocardial infarction (NSTEMI) assisted by the Penumbra Cat RX device (a wide-lumen thrombus aspiration catheter) between May 2019 and February 2021. The primary outcome was the final thrombolysis in myocardial infarction (TIMI) flow. The secondary endpoints were a composite of adverse cardiac events at 6 months. About 50% of the patients did undergo transfemoral PCI as per preference of individual operators. The Penumbra thrombectomy device can be used both by radial and femoral approach and does not need any different guide catheter use.
Results
TIMI flow 3 was achieved in 111 patients (90.2%). The secondary endpoint occurred in 11 patients (8.9%, 3 MI, 8 heart failure hospitalizations). There were no stroke events or device-related complications. The door-to-balloon time was not affected by usage of the Penumbra device. Failure in the restoration of TIMI 3 flow was associated with the use of balloon angioplasty prior to the application of the Penumbra device, leading to distal embolization.
Conclusions
The Penumbra Cat RX provides safe and effective thrombus removal with better clinical outcomes, even in high-risk patients with acute coronary syndrome.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Harrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
- Department of Medicine, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
- Department of Medicine, Aleppo University Hospital, Aleppo, Syria.
ORCID-Profile: Nour Tashtish, Anjan Gupta
Zitieren
APA
Tashtish, N., Chami, T., Dong, T., Chami, B., Al-Kindi, S., Mously, H., Janus, S., Hammad, T., Shishehbor, M. H., & Gupta, A. (2022). Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study. Journal of Interventional Cardiology, 2022, 1-6. https://doi.org/10.1155/2022/5692964
Vancouver
Tashtish N, Chami T, Dong T, Chami B, Al-Kindi S, Mously H, et al. Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study. Journal of Interventional Cardiology. 2022;2022:1-6. doi:10.1155/2022/5692964
BibTeX
@article{Tashtish2022,
author = {Tashtish, Nour and Chami, Tarek and Dong, Tony and Chami, Besher and Al-Kindi, Sadeer and Mously, Haytham and Janus, Scott and Hammad, Tarek and Shishehbor, Mehdi H and Gupta, Anjan},
title = {Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study},
journal = {Journal of Interventional Cardiology},
year = {2022},
volume = {2022},
pages = {1--6},
doi = {10.1155/2022/5692964}
}
EUVIMED