Hip and Knee Joint Angles Determine Fatigue Onset during Quadriceps Neuromuscular Electrical Stimulation
Applied Bionics and Biomechanics · 22.07.2022 · 2022 · 1-11
DOI: 10.1155/2022/4612867 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Bionics and Biomechanics, erschienen am 22.07.2022. Verfasst von Jonathan Galvão Tenório Cavalcante und 7 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Program of Rehabilitation Sciences, University of Brasília, Distrito Federal, Brazil. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidade de Brasília, Fundação de Amparo à Pesquisa do Distrito Federal, Conselho Nacional de Desenvolvimento Científico e Tecnológico.
Abstract (Originalsprache)
Neuromuscular electrical stimulation (NMES) has been used to increase muscle strength and physical function. However, NMES induces rapid fatigue, limiting its application. To date, the effect of quadriceps femoris (QF) muscle length by knee and hip joint manipulation on NMES-induced contraction fatigability is not clear. We aimed to quantify the effects of different muscle lengths on NMES-induced contraction fatigability, fatigue index, and electromyographic (EMG) activity for QF muscle. QF maximum evoked contraction (QMEC) was applied in a 26 min protocol (10 s on; 120 s off; 12 contractions) in 20 healthy participants ( 24.0 ± 4.6 years old), over 4 sessions on different days to test different conditions. The tested conditions were as follows: supine with knee flexion of 60° (SUP60), seated with knee flexion of 60° (SIT60), supine with knee flexion of 20° (SUP20), and seated with knee flexion of 20° (SIT20). Contraction fatigability (torque decline assessed by maximal voluntary contraction [MVC] and during NMES), fatigue index (percentage reduction in MVC), and EMG activity (root mean square [RMS] and median frequency) of the superficial QF’ constituents were assessed. After NMES, all positions except SUP20 had an absolute reduction in MVC ( p < .001 ). Fatigue index was greater in SIT20 than in SIT60 ( p < .001 ) and SUP20 ( p = .01 ). There was significant torque reduction across the 12 QMEC in SUP60 and SIT60, up to 10.5% ( p < .001 – .005 ) and 9.49% ( p < .001 – .033 ), respectively. There was no torque reduction during NMES in SUP20 and SIT20. Fatigue was accompanied by an increase in RMS ( p = .032 ) and a decrease in median frequency for SUP60 ( p < .001 ). Median frequency increased only in the SUP20 condition ( p = .021 ). We concluded that QF NMES-induced contraction fatigability is greater when the knee is flexed at 60° compared to 20°. In addition, a supine position promotes earlier fatigue for a 60° knee flexion, but it delays fatigue onset for a 20° knee flexion compared to the seated position. These results provide a rationale for lower limb positioning during NMES, which depends on training objectives, e.g., strengthening or task-specific functionality training.
Autor:innen und Institutionen
- Graduate Program of Rehabilitation Sciences, University of Brasília, Distrito Federal, Brazil.
- Graduate Program of Physical Education, University of Brasília, Distrito Federal, Brazil.
- Undergraduate Program of Physical Therapy from University of Brasília, Distrito Federal, Brazil.
- Graduate Program of Sciences and Technology of Health, University of Brasília, Distrito Federal, Brazil.
- Centre d'Expertise de la Performance, INSERM UMR1093-CAPS, University of Burgundy Franche-Comté, UFR des Sciences du Sport, F-21000 Dijon, France.
ORCID-Profile: Jonathan Galvão Tenório Cavalcante, Álvaro de Almeida Ventura, Leandro Gomes de Jesus Ferreira, Alessandra Martins Melo de Sousa, Ivo Vieira de Sousa Neto, Rita de Cássia Marqueti, Nicolas Babault, João Luiz Quagliotti Durigan
Förderung
- Universidade de Brasília
- Fundação de Amparo à Pesquisa do Distrito Federal
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Cavalcante, J. G. T., de Almeida Ventura, Á., de Jesus Ferreira, L. G., de Sousa, A. M. M., de Sousa Neto, I. V., de Cássia Marqueti, R., Babault, N., & Durigan, J. L. Q. (2022). Hip and Knee Joint Angles Determine Fatigue Onset during Quadriceps Neuromuscular Electrical Stimulation. Applied Bionics and Biomechanics, 2022, 1-11. https://doi.org/10.1155/2022/4612867
Vancouver
Cavalcante JGT, de Almeida Ventura Á, de Jesus Ferreira LG, de Sousa AMM, de Sousa Neto IV, de Cássia Marqueti R, et al. Hip and Knee Joint Angles Determine Fatigue Onset during Quadriceps Neuromuscular Electrical Stimulation. Applied Bionics and Biomechanics. 2022;2022:1-11. doi:10.1155/2022/4612867
BibTeX
@article{Cavalcante2022,
author = {Cavalcante, Jonathan Galvão Tenório and de Almeida Ventura, Álvaro and de Jesus Ferreira, Leandro Gomes and de Sousa, Alessandra Martins Melo and de Sousa Neto, Ivo Vieira and de Cássia Marqueti, Rita and Babault, Nicolas and Durigan, João Luiz Quagliotti},
title = {Hip and Knee Joint Angles Determine Fatigue Onset during Quadriceps Neuromuscular Electrical Stimulation},
journal = {Applied Bionics and Biomechanics},
year = {2022},
volume = {2022},
pages = {1--11},
doi = {10.1155/2022/4612867}
}
EUVIMED