EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Artificial Intelligence Enabled Fully Automated CMR Function Quantification for Optimized Risk Stratification in Patients Undergoing Transcatheter Aortic Valve Replacement

Ruben Evertz iD, Torben Lange iD, Sören J Backhaus iD, Alexander Schulz, Bo Eric Beuthner, Rodi Topci iD, Karl Toischer, Miriam Puls, Johannes T Kowallick, Gerd Hasenfuß, Andreas Schuster iD

Journal of Interventional Cardiology · 20.04.2022 · 2022 · 1-9

DOI: 10.1155/2022/1368878 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Interventional Cardiology, erschienen am 20.04.2022. Verfasst von Ruben Evertz und 10 weiteren Autor:innen. Beteiligte Einrichtung: University Medical Center Göttingen (UMG), Department of Cardiology and Pneumology, Göttingen, Germany. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Transcatheter Aortic Valve Replacement. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cardiovascular magnetic resonance imaging is considered the reference standard for assessing cardiac morphology and function and has demonstrated prognostic utility in patients undergoing transcatheter aortic valve replacement (TAVR). Novel fully automated analyses may facilitate data analyses but have not yet been compared against conventional manual data acquisition in patients with severe aortic stenosis (AS).

Methods

Fully automated and manual biventricular assessments were performed in 139 AS patients scheduled for TAVR using commercially available software (suiteHEART®, Neosoft; QMass®, Medis Medical Imaging Systems). Volumetric assessment included left ventricular (LV) mass, LV/right ventricular (RV) end-diastolic/end-systolic volume, LV/RV stroke volume, and LV/RV ejection fraction (EF). Results of fully automated and manual analyses were compared. Regression analyses and receiver operator characteristics including area under the curve (AUC) calculation for prediction of the primary study endpoint cardiovascular (CV) death were performed.

Results

Fully automated and manual assessment of LVEF revealed similar prediction of CV mortality in univariable (manual: hazard ratio (HR) 0.970 (95% CI 0.943–0.997) p = 0.032 ; automated: HR 0.967 (95% CI 0.939–0.995) p = 0.022 ) and multivariable analyses (model 1: (including significant univariable parameters) manual: HR 0.968 (95% CI 0.938–0.999) p = 0.043 ; automated: HR 0.963 [95% CI 0.933–0.995] p = 0.024 ; model 2: (including CV risk factors) manual: HR 0.962 (95% CI 0.920–0.996) p = 0.027 ; automated: HR 0.954 (95% CI 0.920–0.989) p = 0.011 ). There were no differences in AUC (LVEF fully automated: 0.686; manual: 0.661; p = 0.21 ). Absolute values of LV volumes differed significantly between automated and manual approaches ( p < 0.001 for all). Fully automated quantification resulted in a time saving of 10 minutes per patient.

Conclusion

Fully automated biventricular volumetric assessments enable efficient and equal risk prediction compared to conventional manual approaches. In addition to significant time saving, this may provide the tools for optimized clinical management and stratification of patients with severe AS undergoing TAVR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementAortic ValveArtificial IntelligenceHumansRisk AssessmentStroke VolumeVentricular Function, Left

Autor:innen und Institutionen

  • University Medical Center Göttingen (UMG), Department of Cardiology and Pneumology, Göttingen, Germany.
  • German Center for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany.
  • University Medical Center Göttingen (UMG), Department of Diagnostic & Interventional Radiology, Göttingen, Germany.

ORCID-Profile: Ruben Evertz, Torben Lange, Sören J Backhaus, Rodi Topci, Andreas Schuster

Zitieren

APA

Evertz, R., Lange, T., Backhaus, S. J., Schulz, A., Beuthner, B. E., Topci, R., Toischer, K., Puls, M., Kowallick, J. T., Hasenfuß, G., & Schuster, A. (2022). Artificial Intelligence Enabled Fully Automated CMR Function Quantification for Optimized Risk Stratification in Patients Undergoing Transcatheter Aortic Valve Replacement. Journal of Interventional Cardiology, 2022, 1-9. https://doi.org/10.1155/2022/1368878

Vancouver

Evertz R, Lange T, Backhaus SJ, Schulz A, Beuthner BE, Topci R, et al. Artificial Intelligence Enabled Fully Automated CMR Function Quantification for Optimized Risk Stratification in Patients Undergoing Transcatheter Aortic Valve Replacement. Journal of Interventional Cardiology. 2022;2022:1-9. doi:10.1155/2022/1368878

BibTeX
@article{Evertz2022,
  author = {Evertz, Ruben and Lange, Torben and Backhaus, Sören J and Schulz, Alexander and Beuthner, Bo Eric and Topci, Rodi and Toischer, Karl and Puls, Miriam and Kowallick, Johannes T and Hasenfuß, Gerd and Schuster, Andreas},
  title = {Artificial Intelligence Enabled Fully Automated CMR Function Quantification for Optimized Risk Stratification in Patients Undergoing Transcatheter Aortic Valve Replacement},
  journal = {Journal of Interventional Cardiology},
  year = {2022},
  volume = {2022},
  pages = {1--9},
  doi = {10.1155/2022/1368878}
}
Kostenlos starten →