Fachartikel in der Zeitschrift Scanning, erschienen am 06.05.2021. Verfasst von Cristina Retana-Lobo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Sciences, University of Costa Rica, Montes de Oca, San José 11502, Costa Rica. Hauptthemen laut MEDLINE: Gutta-Percha, Root Canal Filling Materials. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad de Costa Rica.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the push-out bond strength of premixed and powder-liquid bioceramic sealers with or without gutta-percha (GP) cone. Materials and Methods. Radicular dentin samples were prepared from 80 single-rooted human teeth. After root canal preparation using ProTaper® and irrigation with NaOCl and EDTA, teeth were divided according to the root canal sealer ( n = 20 ): AH Plus®, EndoSequence® BC Sealer™, ProRoot® Endo Sealer, and BioRoot™ RCS. Samples were randomly divided into two subgroups ( n = 10 ): GP-S: root canal filling using the single-cone technique, or S: filling with only sealer. Specimens were kept at 37°C and 100% humidity in calcium-free PBS for 30 days. The push-out bond strength was measured in MPa. Fractured specimens were observed at 25x to evaluate the type of failure. pH and calcium ion release were measured at different experimental periods. Raman and SEM-EDAX analyses were performed for root canal sealers. Data were analysed using three-way analysis of variance (ANOVA) and post hoc Tukey test at a significance of P < 0.05 .

Results

Push-out bond strength was greater for samples obturated with only sealers (S) than samples obturated with the single-cone technique (GP-S) ( P < 0.05 ). BioRoot™ RCS had greater bond strength than EndoSequence® BC Sealer™. Adhesive failures between cement and gutta-percha cone (87.5%) were predominant in the GP-S. Cohesive failures were predominant for S (80%). BioRoot™ RCS and ProRoot® ES presented higher alkalinization potential than the premixed sealer (EndoSequence® BC Sealer™). Powder-liquid bioceramic sealers (BioRoot™ RCS and ProRoot® ES) released the highest cumulative amount of calcium (28.46 mg/L and 20.05 mg/L).

Conclusion

Push-out test without gutta-percha cone presents higher bond strength for bioceramic sealers. Powder-liquid calcium silicate-based sealers present greater bioactivity related to alkalinization potential and calcium ion release.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gutta-PerchaRoot Canal Filling MaterialsEpoxy ResinsHumansPowdersRoot Canal Obturation

Substanzen

Epoxy ResinsPowdersRoot Canal Filling MaterialsGutta-Percha

Autor:innen und Institutionen

  • Department of Restorative Sciences, University of Costa Rica, Montes de Oca, San José 11502, Costa Rica.
  • Department of Restorative Dentistry, Universidade Estadual Paulista (UNESP), Araraquara, SP 14800-903, Brazil.

ORCID-Profile: Mario Tanomaru-Filho, Juliane Maria Guerreiro-Tanomaru, Jessie Reyes-Carmona

Förderung

  • Universidad de Costa Rica

Zitieren

APA

Retana-Lobo, C., Tanomaru-Filho, M., Guerreiro-Tanomaru, J. M., Benavides-García, M., Hernández-Meza, E., & Reyes-Carmona, J. (2021). Push-Out Bond Strength, Characterization, and Ion Release of Premixed and Powder-Liquid Bioceramic Sealers with or without Gutta-Percha. Scanning, 2021, 1-12. https://doi.org/10.1155/2021/6617930

Vancouver

Retana-Lobo C, Tanomaru-Filho M, Guerreiro-Tanomaru JM, Benavides-García M, Hernández-Meza E, Reyes-Carmona J. Push-Out Bond Strength, Characterization, and Ion Release of Premixed and Powder-Liquid Bioceramic Sealers with or without Gutta-Percha. Scanning. 2021;2021:1-12. doi:10.1155/2021/6617930

BibTeX
@article{RetanaLobo2021,
  author = {Retana-Lobo, Cristina and Tanomaru-Filho, Mario and Guerreiro-Tanomaru, Juliane Maria and Benavides-García, Marianella and Hernández-Meza, Erick and Reyes-Carmona, Jessie},
  title = {Push-Out Bond Strength, Characterization, and Ion Release of Premixed and Powder-Liquid Bioceramic Sealers with or without Gutta-Percha},
  journal = {Scanning},
  year = {2021},
  volume = {2021},
  pages = {1--12},
  doi = {10.1155/2021/6617930}
}
Kostenlos starten →