Study on the Curative Effect and Safety of Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation via Zero-Fluoroscopy Transseptal Puncture under the Dual Guidance of Electroanatomical Mapping and Intracardiac Echocardiography

Fei Hang, Liting Cheng, Zhuo Liang, Ruiqing Dong, Xinlu Wang, Ziyu Wang, Zefeng Wang iD, Yongquan Wu iD

Cardiology Research and Practice · 24.05.2021 · 2021 · 1-6

DOI: 10.1155/2021/5561574 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiology Research and Practice, erschienen am 24.05.2021. Verfasst von Fei Hang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

3D electroanatomical mapping combined with intracardiac echocardiography- (EAM-ICE-) guided transseptal puncture has been proven safe and effective during the radiofrequency catheter ablation (RFCA) procedure used to treat paroxysmal atrial fibrillation (PAF). In this study, we aimed to compare the curative effect and safety of RFCA via F (fluoroscopy) and zero-fluoroscopy transseptal puncture guided by EAM-ICE in patients with PAF. Methods and Results. A prospective study in which 110 patients with PAF were included and assigned to two groups was conducted. Fifty-five (50%) patients were enrolled in the EAM-ICE group, whereas the other 55 (50%) patients were enrolled in the F group. There were no significant differences in baseline characteristics between the two groups. The transseptal duration time was longer in the EAM-ICE group (19.8 ± 3.0 min vs. 8.6 ± 1.2 min, p ≤ 0.01 ); however, fluoroscopy was not used in the EAM-ICE group compared with the F group (0 mGy vs. 109.1 ± 57.9 mGy). Similarly, there was also no significant difference in the recurrence rate of atrial fibrillation between the EAM-ICE and F groups (25.5% vs. 18.2%, p = 0.356 ).

Conclusion

RFCA via EAM-ICE-guided zero-fluoroscopy transseptal puncture in patients with PAF is safe and effective for long-term follow-up.

Autor:innen und Institutionen

  • Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, China.

ORCID-Profile: Zefeng Wang, Yongquan Wu

Zitieren

APA

Hang, F., Cheng, L., Liang, Z., Dong, R., Wang, X., Wang, Z., Wang, Z., & Wu, Y. (2021). Study on the Curative Effect and Safety of Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation via Zero-Fluoroscopy Transseptal Puncture under the Dual Guidance of Electroanatomical Mapping and Intracardiac Echocardiography. Cardiology Research and Practice, 2021, 1-6. https://doi.org/10.1155/2021/5561574

Vancouver

Hang F, Cheng L, Liang Z, Dong R, Wang X, Wang Z, et al. Study on the Curative Effect and Safety of Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation via Zero-Fluoroscopy Transseptal Puncture under the Dual Guidance of Electroanatomical Mapping and Intracardiac Echocardiography. Cardiology Research and Practice. 2021;2021:1-6. doi:10.1155/2021/5561574

BibTeX
@article{Hang2021,
  author = {Hang, Fei and Cheng, Liting and Liang, Zhuo and Dong, Ruiqing and Wang, Xinlu and Wang, Ziyu and Wang, Zefeng and Wu, Yongquan},
  title = {Study on the Curative Effect and Safety of Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation via Zero-Fluoroscopy Transseptal Puncture under the Dual Guidance of Electroanatomical Mapping and Intracardiac Echocardiography},
  journal = {Cardiology Research and Practice},
  year = {2021},
  volume = {2021},
  pages = {1--6},
  doi = {10.1155/2021/5561574}
}
Kostenlos starten →