EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty

Kenta Konno iD, Shigeo Hagiwara iD, Junichi Nakamura, Yuya Kawarai, Sumihisa Orita, Yawara Eguchi, Seiji Ohtori

Advances in Orthopedics · 16.09.2021 · 2021 · 1-9

DOI: 10.1155/2021/3705789 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Orthopedics, erschienen am 16.09.2021. Verfasst von Kenta Konno und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Takeda Science Foundation, Japan Osteoporosis Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In primary and revision total hip arthroplasty, to prevent perioperative complications, the prediction of the optimal implant size is essential. Using three-dimensional computed tomography-based postoperative evaluation software, we explored the accuracy and the precision of measurement of the size, alignment, and position of the prosthetic components after total hip arthroplasty.

Methods

Using postoperative evaluation software, the postoperative computed tomography data from 20 hips in 20 patients were evaluated. The component size, alignment, and three-dimensional positioning of the cup and stem were assessed. The concordance rates of the component, repeatability (intraobserver reliability), and reproducibility (interobserver reliability) of postoperative evaluation were calculated. The radiographic inclination and radiographic anteversion of the cup, anteversion, varus–valgus angle, and flexion–extension angles of the stem were measured for alignment. The implant positioning was measured along three axes, namely, X-axis (transverse), Y-axis (sagittal), and Z-axis (longitudinal).

Results

The concordance rates of all parts are above 94%. The intraobserver and interobserver intraclass correlation coefficients of alignment measurement were very good for both cup (0.879–0.964) and stem (0.973–0.996). The intraobserver and interobserver intraclass correlation coefficients of cup positioning were very good (0.961–0.987) for all axes. The intraobserver and interobserver intraclass correlation coefficients of implant positioning were very good for the stem (0.879–0.995) for all axes.

Conclusions

Computed tomography-based postoperative evaluation software was able to evaluate the size and position of total hip implants with high reproducibility.

Autor:innen und Institutionen

  • Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670, Japan.

ORCID-Profile: Kenta Konno, Shigeo Hagiwara

Förderung

  • Japan Society for the Promotion of Science
  • Takeda Science Foundation
  • Japan Osteoporosis Foundation
  • Futaba Foundation and Novartis Research Grant

Zitieren

APA

Konno, K., Hagiwara, S., Nakamura, J., Kawarai, Y., Orita, S., Eguchi, Y., & Ohtori, S. (2021). Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty. Advances in Orthopedics, 2021, 1-9. https://doi.org/10.1155/2021/3705789

Vancouver

Konno K, Hagiwara S, Nakamura J, Kawarai Y, Orita S, Eguchi Y, et al. Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty. Advances in Orthopedics. 2021;2021:1-9. doi:10.1155/2021/3705789

BibTeX
@article{Konno2021,
  author = {Konno, Kenta and Hagiwara, Shigeo and Nakamura, Junichi and Kawarai, Yuya and Orita, Sumihisa and Eguchi, Yawara and Ohtori, Seiji},
  title = {Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty},
  journal = {Advances in Orthopedics},
  year = {2021},
  volume = {2021},
  pages = {1--9},
  doi = {10.1155/2021/3705789}
}
Kostenlos starten →