Automated Estimation of Acute Infarct Volume from Noncontrast Head CT Using Image Intensity Inhomogeneity Correction
International Journal of Biomedical Imaging · 21.08.2019 · 2019 · 1-8
DOI: 10.1155/2019/1720270 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Biomedical Imaging, erschienen am 21.08.2019. Verfasst von Keith A Cauley und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Geisinger, Danville, PA 17821, USA. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Geisinger Clinical Research.
Abstract (Originalsprache)
Identification of early ischemic changes (EIC) on noncontrast head CT scans performed within the first few hours of stroke onset may have important implications for subsequent treatment, though early stroke is poorly delimited on these studies. Lack of sharp lesion boundary delineation in early infarcts precludes manual volume measures, as well as measures using edge-detection or region-filling algorithms. We wished to test a hypothesis that image intensity inhomogeneity correction may provide a sensitive method for identifying the subtle regional hypodensity which is characteristic of early ischemic infarcts. A digital image analysis algorithm was developed using image intensity inhomogeneity correction (IIC) and intensity thresholding. Two different IIC algorithms (FSL and ITK) were compared. The method was evaluated using simulated infarcts and clinical cases. For synthetic infarcts, measured infarct volumes demonstrated strong correlation to the true lesion volume (for 20% decreased density “infarcts,” Pearson r = 0.998 for both algorithms); both algorithms demonstrated improved accuracy with increasing lesion size and decreasing lesion density. In clinical cases (41 acute infarcts in 30 patients), calculated infarct volumes using FSL IIC correlated with the ASPECTS scores (Pearson r = 0.680) and the admission NIHSS (Pearson r = 0.544). Calculated infarct volumes were highly correlated with the clinical decision to treat with IV-tPA. Image intensity inhomogeneity correction, when applied to noncontrast head CT, provides a tool for image analysis to aid in detection of EIC, as well as to evaluate and guide improvements in scan quality for optimal detection of EIC.
Autor:innen und Institutionen
- Department of Radiology, Geisinger, Danville, PA 17821, USA.
- Department of Imaging Science & Innovation, Geisinger, Danville, PA 17821, USA.
- Department of Medical & Health Physics, Geisinger, Danville, PA 17837, USA.
ORCID-Profile: Keith A Cauley
Förderung
- Geisinger Clinical Research
Zitieren
APA
Cauley, K. A., Mongelluzzo, G. J., & Fielden, S. W. (2019). Automated Estimation of Acute Infarct Volume from Noncontrast Head CT Using Image Intensity Inhomogeneity Correction. International Journal of Biomedical Imaging, 2019, 1-8. https://doi.org/10.1155/2019/1720270
Vancouver
Cauley KA, Mongelluzzo GJ, Fielden SW. Automated Estimation of Acute Infarct Volume from Noncontrast Head CT Using Image Intensity Inhomogeneity Correction. International Journal of Biomedical Imaging. 2019;2019:1-8. doi:10.1155/2019/1720270
BibTeX
@article{Cauley2019,
author = {Cauley, Keith A and Mongelluzzo, Gino J and Fielden, Samuel W},
title = {Automated Estimation of Acute Infarct Volume from Noncontrast Head CT Using Image Intensity Inhomogeneity Correction},
journal = {International Journal of Biomedical Imaging},
year = {2019},
volume = {2019},
pages = {1--8},
doi = {10.1155/2019/1720270}
}
EUVIMED