Different Setting Conditions Affect Surface Characteristics and Microhardness of Calcium Silicate-Based Sealers
Scanning · 2018 · 2018 · 1-11
DOI: 10.1155/2018/7136345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scanning, 2018. Verfasst von Dong-Kyu Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry, College of Dentistry, Gangnam Severance Hospital, Yonsei University, 211 Eonju-ro, Gangnam-gu, Seoul 135-720, R…. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, ICT and Future Planning.
Abstract (Originalsprache)
Objective
To investigate the effect of different setting conditions on surface microhardness and setting properties of calcium silicate-based sealers.
Methods
Three sealers, EndoSequence Bioceramic (BC; Brasseler USA, Savannah, GA, USA), Endoseal MTA (ES; Maruchi, Wonju, Korea), and Well-Root ST (WR; Vericom, Chuncheon, Korea), were compared. Specimens were exposed to either butyric acid (pH 5.4) or phosphate-buffered saline (PBS [pH 7.4]) for 48 h and stored at 100% humidity for 12 days. The control specimens were stored at 100% humidity for 14 days. Surface microhardness was measured, topographic changes were observed, and phase analysis was performed using X-ray diffraction. Microhardness according to storage conditions was compared using one-way analysis of variance and Tukey’s multiple comparison tests ( P < . 05 ).
Results
The BC and ES sealers exhibited decreased microhardness when stored in acid or PBS compared with control ( P < . 05 ). In the WR group, acid exposure lowered microhardness of the specimens compared with control ( P < . 05 ). Scanning electron microscopy revealed different topographies in specimens from all tested sealers exposed to acid or PBS.
Conclusion
The surface microhardness of calcium silicate-based sealers was reduced by exposure to either acid or PBS. Acid solutions, however, had a more detrimental effect than PBS.
Autor:innen und Institutionen
- Department of Conservative Dentistry, College of Dentistry, Gangnam Severance Hospital, Yonsei University, 211 Eonju-ro, Gangnam-gu, Seoul 135-720, Republic of Korea.
- Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 120-752, Republic of Korea.
- Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Gangnam Severance Hospital, Yonsei University, 211 Eonju-ro, Gangnam-gu, Seoul 135-720, Republic of Korea.
ORCID-Profile: Dong-Kyu Yang, Sunil Kim, Euiseong Kim, Su-Jung Shin
Förderung
- Ministry of Science, ICT and Future Planning
Zitieren
APA
Yang, D. K., Kim, S., Park, J. W., Kim, E., & Shin, S. J. (2018). Different Setting Conditions Affect Surface Characteristics and Microhardness of Calcium Silicate-Based Sealers. Scanning, 2018, 1-11. https://doi.org/10.1155/2018/7136345
Vancouver
Yang DK, Kim S, Park JW, Kim E, Shin SJ. Different Setting Conditions Affect Surface Characteristics and Microhardness of Calcium Silicate-Based Sealers. Scanning. 2018;2018:1-11. doi:10.1155/2018/7136345
BibTeX
@article{Yang2018,
author = {Yang, Dong-Kyu and Kim, Sunil and Park, Jeong-Won and Kim, Euiseong and Shin, Su-Jung},
title = {Different Setting Conditions Affect Surface Characteristics and Microhardness of Calcium Silicate-Based Sealers},
journal = {Scanning},
year = {2018},
volume = {2018},
pages = {1--11},
doi = {10.1155/2018/7136345}
}
EUVIMED