EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of the Ceiling-Mounted Radiation Shielding Position on the Physician’s Dose from Scatter Radiation during Interventional Procedures

Lucie Sukupova iD, Ondrej Hlavacek, Daniel Vedlich

Radiology Research and Practice · 2018 · 2018 · 1-7

DOI: 10.1155/2018/4287973 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology Research and Practice, 2018. Verfasst von Lucie Sukupova und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of the Director, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Health, Czech Republic.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The effect of the ceiling-mounted radiation shielding on the amount of the scatter radiation was assessed under conditions simulating obese patients for clinically relevant exposure parameters. Measurements were performed in different projections and with different positions of the ceiling-mounted shielding: without shielding; shielding closest to the patient; and shielding closest to the physician performing the procedure. The protection provided by the shielding was assessed for cardiology when the femoral access is used and for radiology when the physician performs the procedure in the abdominal area. The results show that the use of the ceiling-mounted shielding can decrease the dose from the scatter radiation by 95% at the position of the performing physician. In cardiology, the impact is more pronounced when the left oblique projection is used. In radiology, a large decrease was observed for right oblique projections, compared to cardiology. The ceiling-mounted shielding should be placed as close to the physician as possible. The idea of creating the largest radiation shadow by placing the radiation shielding as close to the patient as possible does not provide as effective radiation protection of the operator as it might be thought.

Autor:innen und Institutionen

  • Department of the Director, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic.
  • Radiodiagnostic and Interventional Radiology Department, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic.

ORCID-Profile: Lucie Sukupova

Förderung

  • Ministry of Health, Czech Republic

Zitieren

APA

Sukupova, L., Hlavacek, O., & Vedlich, D. (2018). Impact of the Ceiling-Mounted Radiation Shielding Position on the Physician’s Dose from Scatter Radiation during Interventional Procedures. Radiology Research and Practice, 2018, 1-7. https://doi.org/10.1155/2018/4287973

Vancouver

Sukupova L, Hlavacek O, Vedlich D. Impact of the Ceiling-Mounted Radiation Shielding Position on the Physician’s Dose from Scatter Radiation during Interventional Procedures. Radiology Research and Practice. 2018;2018:1-7. doi:10.1155/2018/4287973

BibTeX
@article{Sukupova2018,
  author = {Sukupova, Lucie and Hlavacek, Ondrej and Vedlich, Daniel},
  title = {Impact of the Ceiling-Mounted Radiation Shielding Position on the Physician’s Dose from Scatter Radiation during Interventional Procedures},
  journal = {Radiology Research and Practice},
  year = {2018},
  volume = {2018},
  pages = {1--7},
  doi = {10.1155/2018/4287973}
}
Kostenlos starten →