Computer-Aided Cobb Measurement Based on Automatic Detection of Vertebral Slopes Using Deep Neural Network
International Journal of Biomedical Imaging · 2017 · 2017 · 1-6
DOI: 10.1155/2017/9083916 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Biomedical Imaging, 2017. Verfasst von Junhua Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Yunnan University, Kunming 650091, China. Die Arbeit wurde bisher 78-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Yunnan Natural Science Foundation.
Abstract (Originalsprache)
Objective
To develop a computer-aided method that reduces the variability of Cobb angle measurement for scoliosis assessment.
Methods
A deep neural network (DNN) was trained with vertebral patches extracted from spinal model radiographs. The Cobb angle of the spinal curve was calculated automatically from the vertebral slopes predicted by the DNN. Sixty-five in vivo radiographs and 40 model radiographs were analyzed. An experienced surgeon performed manual measurements on the aforementioned radiographs. Two examiners used both the proposed and the manual measurement methods to analyze the aforementioned radiographs.
Results
For model radiographs, the intraclass correlation coefficients were greater than 0.98, and the mean absolute differences were less than 3°. This indicates that the proposed system showed high repeatability for measurements of model radiographs. For the in vivo radiographs, the reliabilities were lower than those from the model radiographs, and the differences between the computer-aided measurement and the manual measurement by the surgeon were higher than 5°.
Conclusion
The variability of Cobb angle measurements can be reduced if the DNN system is trained with enough vertebral patches. Training data of in vivo radiographs must be included to improve the performance of DNN. Significance . Vertebral slopes can be predicted by DNN. The computer-aided system can be used to perform automatic measurements of Cobb angle, which is used to make reliable and objective assessments of scoliosis.
Autor:innen und Institutionen
- Department of Electronic Engineering, Yunnan University, Kunming 650091, China.
- Department of Orthopedics, The First People's Hospital of Yunnan Province, Kunming 650032, China.
ORCID-Profile: Junhua Zhang, Yufeng Zhang
Förderung
- National Natural Science Foundation of China
- Yunnan Natural Science Foundation
Zitieren
APA
Zhang, J., Li, H., Lv, L., & Zhang, Y. (2017). Computer-Aided Cobb Measurement Based on Automatic Detection of Vertebral Slopes Using Deep Neural Network. International Journal of Biomedical Imaging, 2017, 1-6. https://doi.org/10.1155/2017/9083916
Vancouver
Zhang J, Li H, Lv L, Zhang Y. Computer-Aided Cobb Measurement Based on Automatic Detection of Vertebral Slopes Using Deep Neural Network. International Journal of Biomedical Imaging. 2017;2017:1-6. doi:10.1155/2017/9083916
BibTeX
@article{Zhang2017,
author = {Zhang, Junhua and Li, Hongjian and Lv, Liang and Zhang, Yufeng},
title = {Computer-Aided Cobb Measurement Based on Automatic Detection of Vertebral Slopes Using Deep Neural Network},
journal = {International Journal of Biomedical Imaging},
year = {2017},
volume = {2017},
pages = {1--6},
doi = {10.1155/2017/9083916}
}
EUVIMED