EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique

Mark Jeremy Sanders iD

Pulmonary Medicine · 2017 · 2017 · 1-7

DOI: 10.1155/2017/1495867 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Pulmonary Medicine, 2017. Verfasst von Mark Jeremy Sanders. Beteiligte Einrichtung: Clement Clarke International Limited, Edinburgh Way, Harlow, Essex CM20 2TT, UK. Hauptthemen laut MEDLINE: Inhalation. Die Arbeit wurde bisher 83-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Portable inhalers are divisible into those that deliver medication by patient triggering (pMDIs: a gentle slow inhalation) and those that use the patient’s inspiratory effort as the force for deaggregation and delivery (DPIs: a stronger deeper inspiratory effort). Patient confusion and poor technique are commonplace. The use of training tools has become standard practice, and unique amongst these is an inspiratory flow meter (In-Check) which is able to simulate the resistance characteristics of different inhalers and, thereby, guide the patient to the correct effort. In-Check’s origins lie in the 1960s peak expiratory flow meters, the development of the Mini-Wright peak flow meter, and inspiratory flow assessment via the nose during the 1970s–1980s. The current device (In-Check DIAL G16) is the third iteration of the original 1998 training tool, with detailed and ongoing assessments of all common inhaler resistances (including combination and breath-actuated inhaler types) summarised into resistance ranges that are preset within the device. The device works by interpolating one of six ranges with the inspiratory effort. Use of the tool has been shown to be contributory to significant improvements in asthma care and control, and it is being advocated for assessment and training in irreversible lung disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InhalationAdministration, InhalationDry Powder InhalersEquipment DesignHumansMetered Dose InhalersPatient Education as TopicRespiratory Therapy

Autor:innen und Institutionen

  • Clement Clarke International Limited, Edinburgh Way, Harlow, Essex CM20 2TT, UK.

ORCID-Profile: Mark Jeremy Sanders

Zitieren

APA

Sanders, M. J. (2017). Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique. Pulmonary Medicine, 2017, 1-7. https://doi.org/10.1155/2017/1495867

Vancouver

Sanders MJ. Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique. Pulmonary Medicine. 2017;2017:1-7. doi:10.1155/2017/1495867

BibTeX
@article{Sanders2017,
  author = {Sanders, Mark Jeremy},
  title = {Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique},
  journal = {Pulmonary Medicine},
  year = {2017},
  volume = {2017},
  pages = {1--7},
  doi = {10.1155/2017/1495867}
}
Kostenlos starten →