Fachartikel in der Zeitschrift Journal of Pregnancy, 2016. Verfasst von Kaori Michikata und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Center for Perinatal Medicine, University of Miyazaki Faculty of Medicine, Miyazaki 889-1692, Japan. Hauptthemen laut MEDLINE: Perinatology, Specialization. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Culture, Sports, Science, and Technology, JAOG Ogyaa Donation Foundation, University ofMiyazaki Hospital.
Abstract (Originalsprache)
Objective
The improvement of the accuracy of fetal heart rate (FHR) pattern interpretation to improve perinatal outcomes remains an elusive challenge. We examined the impact of an FHR centralization system on the incidence of neonatal acidemia and cesarean births.
Methods
We performed a regional, population-based, before-and-after study of 9,139 deliveries over a 3-year period. The chi-squared test was used for the statistical analysis.
Results
The before-and-after study showed no difference in the rates of acidemia, cesarean births, or perinatal death in the whole population. A subgroup analysis using the 4 hospitals in which an FHR centralization system was continuously connected (compliant group) and 3 hospitals in which the FHR centralization system was connected on demand (noncompliant group) showed that the incidence acidemia was significantly decreased (from 0.47% to 0.11%) without a corresponding increase in the cesarean birth rate due to nonreassuring FHR patterns in the compliant group. Although there was no difference in the incidence of nonreassuring FHR patterns in the noncompliant group, the total cesarean birth rate was significantly higher than that in the compliant group.
Conclusion
The continuous FHR centralization system, in which specialists help to interpret results and decide clinical actions, was beneficial in reducing the incidence of neonatal acidemia (pH < 7.1) without increasing the cesarean birth rate due to nonreassuring FHR patterns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, Center for Perinatal Medicine, University of Miyazaki Faculty of Medicine, Miyazaki 889-1692, Japan.
ORCID-Profile: Kaori Michikata, Hiroshi Sameshima
Förderung
- Ministry of Education, Culture, Sports, Science, and Technology
- JAOG Ogyaa Donation Foundation
- University ofMiyazaki Hospital
- Japan Society for the Promotion of Science
Zitieren
APA
Michikata, K., Sameshima, H., Urabe, H., Tokunaga, S., Kodama, Y., & Ikenoue, T. (2016). The Regional Centralization of Electronic Fetal Heart Rate Monitoring and Its Impact on Neonatal Acidemia and the Cesarean Birth Rate. Journal of Pregnancy, 2016, 1-7. https://doi.org/10.1155/2016/3658527
Vancouver
Michikata K, Sameshima H, Urabe H, Tokunaga S, Kodama Y, Ikenoue T. The Regional Centralization of Electronic Fetal Heart Rate Monitoring and Its Impact on Neonatal Acidemia and the Cesarean Birth Rate. Journal of Pregnancy. 2016;2016:1-7. doi:10.1155/2016/3658527
BibTeX
@article{Michikata2016,
author = {Michikata, Kaori and Sameshima, Hiroshi and Urabe, Hirotoshi and Tokunaga, Syuichi and Kodama, Yuki and Ikenoue, Tsuyomu},
title = {The Regional Centralization of Electronic Fetal Heart Rate Monitoring and Its Impact on Neonatal Acidemia and the Cesarean Birth Rate},
journal = {Journal of Pregnancy},
year = {2016},
volume = {2016},
pages = {1--7},
doi = {10.1155/2016/3658527}
}
EUVIMED