Automatic Labeling of Vertebral Levels Using a Robust Template-Based Approach
International Journal of Biomedical Imaging · 2014 · 2014 · 1-9
DOI: 10.1155/2014/719520 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Biomedical Imaging, 2014. Verfasst von Eugénie Ullmann und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada H3T 1J4. Die Arbeit wurde bisher 71-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Canadian Institute of Health Research, National Multiple Sclerosis Society, Fonds de Recherche du Québec - Santé.
Abstract (Originalsprache)
Context
MRI of the spinal cord provides a variety of biomarkers sensitive to white matter integrity and neuronal function. Current processing methods are based on manual labeling of vertebral levels, which is time consuming and prone to user bias. Although several methods for automatic labeling have been published; they are not robust towards image contrast or towards susceptibility-related artifacts.
Methods
Intervertebral disks are detected from the 3D analysis of the intensity profile along the spine. The robustness of the disk detection is improved by using a template of vertebral distance, which was generated from a training dataset. The developed method has been validated using T 1 - and T 2 -weighted contrasts in ten healthy subjects and one patient with spinal cord injury.
Results
Accuracy of vertebral labeling was 100%. Mean absolute error was 2.1 ± 1.7 mm for T 2 -weighted images and 2.3 ± 1.6 mm for T 1 -weighted images. The vertebrae of the spinal cord injured patient were correctly labeled, despite the presence of artifacts caused by metallic implants.
Discussion
We proposed a template-based method for robust labeling of vertebral levels along the whole spinal cord for T 1 - and T 2 -weighted contrasts. The method is freely available as part of the spinal cord toolbox.
Autor:innen und Institutionen
- Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada H3T 1J4.
- Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada H3T 1J4 ; Functional Neuroimaging Unit, CRIUGM, Université de Montreal, Montreal, QC, Canada H3W 1W5.
ORCID-Profile: Julien Cohen-Adad
Förderung
- Canadian Institute of Health Research
- National Multiple Sclerosis Society
- Fonds de Recherche du Québec - Santé
- Quebec Bioimaging Network
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Ullmann, E., Pelletier Paquette, J. F., Thong, W. E., & Cohen-Adad, J. (2014). Automatic Labeling of Vertebral Levels Using a Robust Template-Based Approach. International Journal of Biomedical Imaging, 2014, 1-9. https://doi.org/10.1155/2014/719520
Vancouver
Ullmann E, Pelletier Paquette JF, Thong WE, Cohen-Adad J. Automatic Labeling of Vertebral Levels Using a Robust Template-Based Approach. International Journal of Biomedical Imaging. 2014;2014:1-9. doi:10.1155/2014/719520
BibTeX
@article{Ullmann2014,
author = {Ullmann, Eugénie and Pelletier Paquette, Jean François and Thong, William E and Cohen-Adad, Julien},
title = {Automatic Labeling of Vertebral Levels Using a Robust Template-Based Approach},
journal = {International Journal of Biomedical Imaging},
year = {2014},
volume = {2014},
pages = {1--9},
doi = {10.1155/2014/719520}
}
EUVIMED