EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Adequacy of the Endometrial Samples Obtained by the Uterine Explora Device and Conventional Dilatation and Curettage: A Comparative Study

Maria Abdulrahim Arafah, Ammar Cherkess Al-Rikabi, Rakia Aljasser, Yaser Adi

International Journal of Reproductive Medicine · 2014

DOI: 10.1155/2014/578193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Reproductive Medicine, 2014. Verfasst von Maria Abdulrahim Arafah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, College of Medicine, King Saud University and King Khalid University Hospital, P.O. Box 7805, Riyadh 11472, Saudi Arabia. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Our aim is to compare the adequacy and diagnostic yield of samples obtained by the endometrial Explora Sampler I-MX120 with endometrial specimens obtained by conventional dilatation and curettage (D&C).

Methods

A total of 1270 endometrial samples were received in the histopathology laboratories at the King Khalid University Hospital, Riyadh, Saudi Arabia, between 2007 and 2010. In the outpatient clinic, the Uterine Explora Model I was used to obtain 996 samples. The remaining 274 samples were obtained by conventional D&C. Sample adequacy and the clustering of inadequate specimens according to age groups by the two different techniques were compared and statistically analyzed.

Results

Out of 1270 endometrial samples, 253 (19.9%) were inadequate. The Uterine Explora was used in 88.5% of these inadequate samples (253 samples), and the remaining 11.5% were obtained by D&C. The insufficient tissue incidence was higher with the Explora (17.6%) than with the D&C (2.2%) and the difference was statistically significant ( P < 0.0001 ) . The ages of the patients, as well as the clinical indications for the procedures, were recorded.

Conclusion

This retrospective study demonstrated better specimen adequacy when D&C was used compared to the higher rate of sample insufficiency obtained with the Explora.

Autor:innen und Institutionen

  • Department of Pathology, College of Medicine, King Saud University and King Khalid University Hospital, P.O. Box 7805, Riyadh 11472, Saudi Arabia.
  • Department of Pathology, College of Medicine, King Saud University and King Khalid University Hospital, P.O. Box 7805, Riyadh 11472, Saudi Arabia ; Department of Pathology, King Saud University, Faculty of Medicine and…
  • Department of Obstetrics and Gynecology, College of Medicine, King Saud University and King Khalid University Hospital, P.O. Box 7805, Riyadh 11472, Saudi Arabia.
  • Sheikh Abdullah Bahamdan's Research Chair for EBHC-KT, King Saud University and King Khalid University Hospital, P.O. Box 7805, Riyadh 11472, Saudi Arabia.

Zitieren

APA

Arafah, M. A., Cherkess Al-Rikabi, A., Aljasser, R., & Adi, Y. (2014). Adequacy of the Endometrial Samples Obtained by the Uterine Explora Device and Conventional Dilatation and Curettage: A Comparative Study. International Journal of Reproductive Medicine. https://doi.org/10.1155/2014/578193

Vancouver

Arafah MA, Cherkess Al-Rikabi A, Aljasser R, Adi Y. Adequacy of the Endometrial Samples Obtained by the Uterine Explora Device and Conventional Dilatation and Curettage: A Comparative Study. International Journal of Reproductive Medicine. 2014. doi:10.1155/2014/578193

BibTeX
@article{Arafah2014,
  author = {Arafah, Maria Abdulrahim and Cherkess Al-Rikabi, Ammar and Aljasser, Rakia and Adi, Yaser},
  title = {Adequacy of the Endometrial Samples Obtained by the Uterine Explora Device and Conventional Dilatation and Curettage: A Comparative Study},
  journal = {International Journal of Reproductive Medicine},
  year = {2014},
  doi = {10.1155/2014/578193}
}
Kostenlos starten →