EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Validation of Shape Context Based Image Registration Method Using Digital Image Correlation Measurement on a Rat Stomach

Donghua Liao, Peng Wang, Jingbo Zhao, Hans Gregersen

Journal of Computational Medicine · 2014

DOI: 10.1155/2014/504656 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Computational Medicine, 2014. Verfasst von Donghua Liao und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Karen Elise Jensens Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recently we developed analysis for 3D visceral organ deformation by combining the shape context (SC) method with a full-field strain (strain distribution on a whole 3D surface) analysis for calculating distension-induced rat stomach deformation. The surface deformation detected by the SC method needs to be further verified by using a feature tracking measurement. Hence, the aim of this study was to verify the SC method-based calculation by using digital image correlation (DIC) measurement on a rat stomach. The rat stomach exposed to distension pressures 0.0, 0.2, 0.4, and 0.6 kPa were studied using both 3D DIC system and SC-based image registration calculation. Three different surface sample counts between the reference and the target surfaces were used to gauge the effect of the surface sample counts on the calculation. Each pair of the surface points between the DIC measured target surface and the SC calculated correspondence surface was compared. Compared with DIC measurement, the SC calculated surface had errors from 5% to 23% at pressures from 0.2 to 0.6 kPa with different surface sample counts between the reference surface and the target surface. This indicates good qualitative and quantitative agreement on the surfaces with small dissimilarity and small sample count difference between the reference surface and the target surface. In conclusion, this is the first study to validate the 3D SC-based image registration method by using unique tracking features measurement. The developed method can be used in the future for analysing scientific and clinical data of visceral organ geometry and biomechanical properties in health and disease.

Förderung

  • Karen Elise Jensens Foundation

Zitieren

APA

Liao, D., Wang, P., Zhao, J., & Gregersen, H. (2014). Validation of Shape Context Based Image Registration Method Using Digital Image Correlation Measurement on a Rat Stomach. Journal of Computational Medicine. https://doi.org/10.1155/2014/504656

Vancouver

Liao D, Wang P, Zhao J, Gregersen H. Validation of Shape Context Based Image Registration Method Using Digital Image Correlation Measurement on a Rat Stomach. Journal of Computational Medicine. 2014. doi:10.1155/2014/504656

BibTeX
@article{Liao2014,
  author = {Liao, Donghua and Wang, Peng and Zhao, Jingbo and Gregersen, Hans},
  title = {Validation of Shape Context Based Image Registration Method Using Digital Image Correlation Measurement on a Rat Stomach},
  journal = {Journal of Computational Medicine},
  year = {2014},
  doi = {10.1155/2014/504656}
}
Kostenlos starten →