EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Diagnostic Performance and Additional Value of Elastosonography in Focal Breast Lesions: Statistical Correlation between Size-Dependant Strain Index Measurements, Multimodality-BI-RADS Score, and Histopathology in a Clinical Routine Setting

Lukas Ebner iD, Harald M Bonel, Adrian Huber, Steffen Ross iD, Andreas Christe

ISRN Radiology · 2014

DOI: 10.1155/2014/396368 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ISRN Radiology, 2014. Verfasst von Lukas Ebner und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department for Diagnostic, Interventional and Pediatric Radiology, University Hospital Inselspital Bern, Freiburgstraße 10, 3010 Bern, Switzerland. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the diagnostic benefit of real-time elastography (RTE) in clinical routine. Strain indices (SI) for benign and malignant tumors were assessed.

Methods

100 patients with 110 focal breast lesions were retrieved. Patients had mammography (MG), ultrasound (US), and, if necessary, MRI. RTE was conducted after ultrasound. Lesions were assessed with BI-RADS for mammography and ultrasound. Diagnosis was established with histology or follow-up.

Results

SI for BI-RADS 2 was 1.71 ± 0.86 . Higher SI ( 2.21 ± 1.96 ) was observed for BI-RADS 3 lesions. SI of BI-RADS 4 and 5 lesions were significantly higher 16.92 ± 20.89 and 19.54 ± 10.41 . 31 malignant tumors exhibited an average SI of 16.13 ± 14.67 ; SI of benign lesions was 5.29 ± 11.87 ( P value < 0.0001 ). ROC analysis threshold was >3.8 for malignant disease. Sensitivity of sonography was 90.3% (specificity 78.5%). RTE showed a sensitivity of 87.1% (specificity 79.7%). Accuracy of all modalities combined was 96.8%. In BI-RADS 3 lesions RTE was able to detect all malignant lesions (sensitivity 100%, specificity 92.9%, and accuracy 93.9%).

Conclusions

RTE increased sensitivity and specificity for breast cancer detection when used in combination with ultrasound.

Autor:innen und Institutionen

  • Department for Diagnostic, Interventional and Pediatric Radiology, University Hospital Inselspital Bern, Freiburgstraße 10, 3010 Bern, Switzerland.
  • Institute of Forensic Medicine, University of Zürich, Virtopsy, 8057 Zurich, Switzerland.

ORCID-Profile: Lukas Ebner, Steffen Ross

Zitieren

APA

Ebner, L., Bonel, H. M., Huber, A., Ross, S., & Christe, A. (2014). Diagnostic Performance and Additional Value of Elastosonography in Focal Breast Lesions: Statistical Correlation between Size-Dependant Strain Index Measurements, Multimodality-BI-RADS Score, and Histopathology in a Clinical Routine Setting. ISRN Radiology. https://doi.org/10.1155/2014/396368

Vancouver

Ebner L, Bonel HM, Huber A, Ross S, Christe A. Diagnostic Performance and Additional Value of Elastosonography in Focal Breast Lesions: Statistical Correlation between Size-Dependant Strain Index Measurements, Multimodality-BI-RADS Score, and Histopathology in a Clinical Routine Setting. ISRN Radiology. 2014. doi:10.1155/2014/396368

BibTeX
@article{Ebner2014,
  author = {Ebner, Lukas and Bonel, Harald M and Huber, Adrian and Ross, Steffen and Christe, Andreas},
  title = {Diagnostic Performance and Additional Value of Elastosonography in Focal Breast Lesions: Statistical Correlation between Size-Dependant Strain Index Measurements, Multimodality-BI-RADS Score, and Histopathology in a Clinical Routine Setting},
  journal = {ISRN Radiology},
  year = {2014},
  doi = {10.1155/2014/396368}
}
Kostenlos starten →