EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 3.0

Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review

Tushar Kanti Bera

Journal of Medical Engineering · 17.06.2014 · 2014 · 1-28

DOI: 10.1155/2014/381251 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Medical Engineering, erschienen am 17.06.2014. Verfasst von Tushar Kanti Bera. Beteiligte Einrichtung: Department of Computational Science and Engineering, Yonsei University, Seoul 120749, Republic of Korea. Die Arbeit wurde bisher 331-mal zitiert (Crossref) und nennt 208 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends.

Autor:innen und Institutionen

  • Department of Computational Science and Engineering, Yonsei University, Seoul 120749, Republic of Korea.

Zitieren

APA

Bera, T. K. (2014). Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review. Journal of Medical Engineering, 2014, 1-28. https://doi.org/10.1155/2014/381251

Vancouver

Bera TK. Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review. Journal of Medical Engineering. 2014;2014:1-28. doi:10.1155/2014/381251

BibTeX
@article{Bera2014,
  author = {Bera, Tushar Kanti},
  title = {Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review},
  journal = {Journal of Medical Engineering},
  year = {2014},
  volume = {2014},
  pages = {1--28},
  doi = {10.1155/2014/381251}
}
Kostenlos starten →