EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor

Valeria Calvi, Giovanni Pizzimenti, Marco Lisi, Giuseppe Doria, Ludovico Vasquez, Francesco Lisi, Salvatore Felis, Donatella Tempio, Alfredo Virgilio, Alberto Barbetta, Franco Di Gregorio

Advances in Medicine · 2014

DOI: 10.1155/2014/307168 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Medicine, 2014. Verfasst von Valeria Calvi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Arrhythmology OU, Ferrarotto Hospital, University of Catania, Catania, Italy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Transvalvular Impedance (TVI) is derived between atrial and ventricular pacing electrodes. A sharp TVI increase in systole is an ejection marker, allowing the hemodynamic surveillance of ventricular stimulation effectiveness in pacemaker patients. At routine follow-up checks, the ventricular threshold test was managed by the stimulator with the supervision of a physician, who monitored the surface ECG. When the energy scan resulted in capture loss, the TVI system must detect the failure and increase the output voltage. A TVI signal suitable to this purpose was present in 85% of the tested patients. A total of 230 capture failures, induced in 115 patients in both supine and sitting upright positions, were all promptly recognized by real-time TVI analysis (100% sensitivity). The procedure was never interrupted by the physician, as the automatic energy regulation ensured full patient’s safety. The pulse energy was then set at 4 times the threshold to test the alarm specificity during daily activity (sitting, standing up, and walking). The median prevalence of false alarms was 0.336%. The study shows that TVI-based ejection assessment is a valuable approach to the verification of pacing reliability and the autoregulation of ventricular stimulation energy.

Autor:innen und Institutionen

  • Arrhythmology OU, Ferrarotto Hospital, University of Catania, Catania, Italy.
  • Arrhythmology OU, Cardiology Department, Fogliani Hospital, Milazzo, Messina, Italy.
  • Arrhythmology OU, Cardiology Department, Cannizzaro Hospital, Catania, Italy.
  • Cardiology Department, Garibaldi-Centro Hospital, Catania, Italy.
  • Clinical Research Unit, Medico Spa, Rubano, Padova, Italy.

Zitieren

APA

Calvi, V., Pizzimenti, G., Lisi, M., Doria, G., Vasquez, L., Lisi, F., Felis, S., Tempio, D., Virgilio, A., Barbetta, A., & Di Gregorio, F. (2014). Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor. Advances in Medicine. https://doi.org/10.1155/2014/307168

Vancouver

Calvi V, Pizzimenti G, Lisi M, Doria G, Vasquez L, Lisi F, et al. Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor. Advances in Medicine. 2014. doi:10.1155/2014/307168

BibTeX
@article{Calvi2014,
  author = {Calvi, Valeria and Pizzimenti, Giovanni and Lisi, Marco and Doria, Giuseppe and Vasquez, Ludovico and Lisi, Francesco and Felis, Salvatore and Tempio, Donatella and Virgilio, Alfredo and Barbetta, Alberto and Di Gregorio, Franco},
  title = {Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor},
  journal = {Advances in Medicine},
  year = {2014},
  doi = {10.1155/2014/307168}
}
Kostenlos starten →