Fachartikel in der Zeitschrift Surgery Research and Practice, 2014. Verfasst von R C L Chan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Division of Head and Neck Surgery, Department of Surgery, Queen Mary Hospital, Hong Kong. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate assessment of irradiated neck in squamous cell carcinoma of the head and neck (HNSCC) is essential. Fine-needle aspiration cytology is often performed for suspicious lesions but it is limited by its low negative predictive value (NPV). We postulated that F-18 fluorodeoxyglucose (FDG) positron emission tomography combined with computed tomography (PET/CT) can overcome this limitation by its high NPV value and allow for a more accurate assessment of irradiated neck in HNSCC.

Methods

Fifty-four HNSCC patients were included for the study. They all received previous irradiation to the neck. Clinical characteristics, details of radiotherapy, PET/CT results, follow-up findings, and final histological diagnosis were analyzed.

Results

The sensitivity, specificity, positive predictive value (PPV), and NPV were 95.8%, 96.7%, 95.8%, and 96.7%, respectively. Age, sex, radiation dose, interval between PET/CT and radiotherapy completion, nature of radiotherapy, and use of second course of radiotherapy were not found to affect diagnostic accuracy of PET/CT. A new algorithm for investigation of masses in irradiated neck is proposed.

Conclusions

PET/CT is an effective diagnostic tool and has a complementary role to FNAC in the management of irradiated neck in head and neck cancers, particularly in cases where suspicious lesions were identified but FNAC showed negative results.

Autor:innen und Institutionen

  • Division of Head and Neck Surgery, Department of Surgery, Queen Mary Hospital, Hong Kong.

Zitieren

APA

Chan, R. C., & Chan, Y. W. (2014). PET/CT Is Complementary to Fine-Needle Aspiration Cytology in Assessment of Irradiated Neck in Head and Neck Cancers. Surgery Research and Practice. https://doi.org/10.1155/2014/191267

Vancouver

Chan RC, Chan YW. PET/CT Is Complementary to Fine-Needle Aspiration Cytology in Assessment of Irradiated Neck in Head and Neck Cancers. Surgery Research and Practice. 2014. doi:10.1155/2014/191267

BibTeX
@article{Chan2014,
  author = {Chan, R C L and Chan, Y W},
  title = {PET/CT Is Complementary to Fine-Needle Aspiration Cytology in Assessment of Irradiated Neck in Head and Neck Cancers},
  journal = {Surgery Research and Practice},
  year = {2014},
  doi = {10.1155/2014/191267}
}
Kostenlos starten →