Detection of Myoglobin with an Open-Cavity-Based Label-Free Photonic Crystal Biosensor
Journal of Medical Engineering · 2013
DOI: 10.1155/2013/808056 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Engineering, 2013. Verfasst von Bailin Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: San Antonio Area Foundation.
Abstract (Originalsprache)
The label-free detection of one of the cardiac biomarkers, myoglobin, using a photonic-crystal-based biosensor in a total-internal-reflection configuration (PC-TIR) is presented in this paper. The PC-TIR sensor possesses a unique open optical microcavity that allows for several key advantages in biomolecular assays. In contrast to a conventional closed microcavity, the open configuration allows easy functionalization of the sensing surface for rapid biomolecular binding assays. Moreover, the properties of PC structures make it easy to be designed and engineered for operating at any optical wavelength. Through fine design of the photonic crystal structure, biochemical modification of the sensor surface, and integration with a microfluidic system, we have demonstrated that the detection sensitivity of the sensor for myoglobin has reached the clinically significant concentration range, enabling potential usage of this biosensor for diagnosis of acute myocardial infarction. The real-time response of the sensor to the myoglobin binding may potentially provide point-of-care monitoring of patients and treatment effects.
Autor:innen und Institutionen
- University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249, USA.
Förderung
- San Antonio Area Foundation
Zitieren
APA
Zhang, B., Tamez-Vela, J. M., Solis, S., Bustamante, G., Peterson, R., Rahman, S., Morales, A., Tang, L., & Ye, J. Y. (2013). Detection of Myoglobin with an Open-Cavity-Based Label-Free Photonic Crystal Biosensor. Journal of Medical Engineering. https://doi.org/10.1155/2013/808056
Vancouver
Zhang B, Tamez-Vela JM, Solis S, Bustamante G, Peterson R, Rahman S, et al. Detection of Myoglobin with an Open-Cavity-Based Label-Free Photonic Crystal Biosensor. Journal of Medical Engineering. 2013. doi:10.1155/2013/808056
BibTeX
@article{Zhang2013,
author = {Zhang, Bailin and Tamez-Vela, Juan Manuel and Solis, Steven and Bustamante, Gilbert and Peterson, Ralph and Rahman, Shafiqur and Morales, Andres and Tang, Liang and Ye, Jing Yong},
title = {Detection of Myoglobin with an Open-Cavity-Based Label-Free Photonic Crystal Biosensor},
journal = {Journal of Medical Engineering},
year = {2013},
doi = {10.1155/2013/808056}
}
EUVIMED