Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance

Linnea Jarenbäck, Jaro Ankerst, Leif Bjermer, Ellen Tufvesson

Pulmonary Medicine · 2013 · 2013 · 1-10

DOI: 10.1155/2013/782052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pulmonary Medicine, 2013. Verfasst von Linnea Jarenbäck und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Respiratory Medicine and Allergology, Lund University, 221 84 Lund, Sweden. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Swedish Heart and Lung foundation, Swedish Research Council, Evy and Gunnar Sandberg’s Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Classification of COPD into different GOLD stages is based on forced expiratory volume in 1 s (FEV 1 ) and forced vital capacity (FVC) but has shown to be of limited value. The aim of the study was to relate spirometry values to more advanced measures of lung function in COPD patients compared to healthy smokers. The lung function of 65 COPD patients and 34 healthy smokers was investigated using flow-volume spirometry, body plethysmography, single breath helium dilution with CO-diffusion, and impulse oscillometry. All lung function parameters, measured by body plethysmography, CO-diffusion, and impulse oscillometry, were increasingly affected through increasing GOLD stage but did not correlate with FEV 1 within any GOLD stage. In contrast, they correlated fairly well with FVC%p, FEV 1 /FVC, and inspiratory capacity. Residual volume (RV) measured by body plethysmography increased through GOLD stages, while RV measured by helium dilution decreased. The difference between these RV provided valuable additional information and correlated with most other lung function parameters measured by body plethysmography and CO-diffusion. Airway resistance measured by body plethysmography and impulse oscillometry correlated within COPD stages. Different lung function parameters are of importance in COPD, and a thorough patient characterization is important to understand the disease.

Autor:innen und Institutionen

  • Department of Clinical Sciences, Respiratory Medicine and Allergology, Lund University, 221 84 Lund, Sweden.

Förderung

  • Swedish Heart and Lung foundation
  • Swedish Research Council
  • Evy and Gunnar Sandberg’s Foundation
  • Royal Physiographic Society in Lund

Zitieren

APA

Jarenbäck, L., Ankerst, J., Bjermer, L., & Tufvesson, E. (2013). Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance. Pulmonary Medicine, 2013, 1-10. https://doi.org/10.1155/2013/782052

Vancouver

Jarenbäck L, Ankerst J, Bjermer L, Tufvesson E. Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance. Pulmonary Medicine. 2013;2013:1-10. doi:10.1155/2013/782052

BibTeX
@article{Jarenbck2013,
  author = {Jarenbäck, Linnea and Ankerst, Jaro and Bjermer, Leif and Tufvesson, Ellen},
  title = {Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance},
  journal = {Pulmonary Medicine},
  year = {2013},
  volume = {2013},
  pages = {1--10},
  doi = {10.1155/2013/782052}
}
Kostenlos starten →