Empirical Evaluation of Visual Fatigue from Display Alignment Errors Using Cerebral Hemodynamic Responses

Hanniebey D Wiyor, Celestine A Ntuen

Journal of Medical Engineering · 2013

DOI: 10.1155/2013/521579 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Engineering, 2013. Verfasst von Hanniebey D Wiyor und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial & Systems Engineering, North Carolina A&T State University, 1601 East Market Street, 406 McNair Hall, Greensboro, NC 27411, …. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Army Research Office.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study was to investigate the effect of stereoscopic display alignment errors on visual fatigue and prefrontal cortical tissue hemodynamic responses. We collected hemodynamic data and perceptual ratings of visual fatigue while participants performed visual display tasks on 8 ft × 6 ft NEC LT silver screen with NEC LT 245 DLP projectors. There was statistical significant difference between subjective measures of visual fatigue before air traffic control task (BATC) and after air traffic control task (ATC 3), ( P < 0.05 ). Statistical significance was observed between left dorsolateral prefrontal cortex oxygenated hemoglobin ( l DLPFC-HbO 2 ), left dorsolateral prefrontal cortex deoxygenated hemoglobin ( l DLPFC-Hbb), and right dorsolateral prefrontal cortex deoxygenated hemoglobin ( r DLPFC-Hbb) on stereoscopic alignment errors ( P < 0.05 ). Thus, cortical tissue oxygenation requirement in the left hemisphere indicates that the effect of visual fatigue is more pronounced in the left dorsolateral prefrontal cortex.

Autor:innen und Institutionen

  • Department of Industrial & Systems Engineering, North Carolina A&T State University, 1601 East Market Street, 406 McNair Hall, Greensboro, NC 27411, USA.

Förderung

  • Army Research Office

Zitieren

APA

Wiyor, H. D., & Ntuen, C. A. (2013). Empirical Evaluation of Visual Fatigue from Display Alignment Errors Using Cerebral Hemodynamic Responses. Journal of Medical Engineering. https://doi.org/10.1155/2013/521579

Vancouver

Wiyor HD, Ntuen CA. Empirical Evaluation of Visual Fatigue from Display Alignment Errors Using Cerebral Hemodynamic Responses. Journal of Medical Engineering. 2013. doi:10.1155/2013/521579

BibTeX
@article{Wiyor2013,
  author = {Wiyor, Hanniebey D and Ntuen, Celestine A},
  title = {Empirical Evaluation of Visual Fatigue from Display Alignment Errors Using Cerebral Hemodynamic Responses},
  journal = {Journal of Medical Engineering},
  year = {2013},
  doi = {10.1155/2013/521579}
}
Kostenlos starten →