EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Comparison between Constrained and Semiconstrained Knee Allograft-Prosthesis Composite Reconstructions

German L Farfalli, Luis A Aponte-Tinao, Miguel A Ayerza, D Luis Muscolo, Patrick J Boland, Carol D Morris, Edward A Athanasian, John H Healey

Sarcoma · 2013 · 2013 · 1-8

DOI: 10.1155/2013/489652 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sarcoma, 2013. Verfasst von German L Farfalli und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Orthopaedic Surgery Service, Memorial Sloan-Kettering Cancer Center, Weill Cornell Medical College, Cornell University, New Yo…. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Allograft-prosthesis composite (APC) can restore capsular and ligamentous tissues of the knee sacrificed in a tumor extirpation. We asked if performing APC would restore knee stability and allow the use of nonconstrained arthroplasty while preventing aseptic loosening. We retrospectively compared 50 knee APCs performed with non-constrained revision knee prosthesis (Group 1) with 36 matched APCs performed with a constrained prosthesis (Group 2). In Group 1, the survival rate was 69% at five and 62% at ten years. Sixteen reconstructions were removed due to complications: eight deep infections, three fractures, two instabilities, one aseptic loosening, one local recurrence, and one nonunion. In Group 2, the survival rate was 80% at five and 53% at ten years. Nine reconstructions were removed: 3 due to deep infections, 3 to fractures, and 3 to aseptic loosening. In both groups, we observed more allograft fractures when the prosthetic stem does not bypass the host-donor osteotomy (). Both groups had mainly good or excellent MSTS functional results. Survival rate and functional scores and aseptic loosening were similar in both groups. A rotating-hinge APC is recommended when host-donor soft tissue reconstruction fails to restore knee instability. The use of a short prosthetic stem has a statistical relationship with APC fractures.

Autor:innen und Institutionen

  • Department of Surgery, Orthopaedic Surgery Service, Memorial Sloan-Kettering Cancer Center, Weill Cornell Medical College, Cornell University, New York, NY, USA ; Institute of Orthopedics "Carlos E. Ottolenghi," Italian…

Zitieren

APA

Farfalli, G. L., Aponte-Tinao, L. A., Ayerza, M. A., Muscolo, D. L., Boland, P. J., Morris, C. D., Athanasian, E. A., & Healey, J. H. (2013). Comparison between Constrained and Semiconstrained Knee Allograft-Prosthesis Composite Reconstructions. Sarcoma, 2013, 1-8. https://doi.org/10.1155/2013/489652

Vancouver

Farfalli GL, Aponte-Tinao LA, Ayerza MA, Muscolo DL, Boland PJ, Morris CD, et al. Comparison between Constrained and Semiconstrained Knee Allograft-Prosthesis Composite Reconstructions. Sarcoma. 2013;2013:1-8. doi:10.1155/2013/489652

BibTeX
@article{Farfalli2013,
  author = {Farfalli, German L and Aponte-Tinao, Luis A and Ayerza, Miguel A and Muscolo, D Luis and Boland, Patrick J and Morris, Carol D and Athanasian, Edward A and Healey, John H},
  title = {Comparison between Constrained and Semiconstrained Knee Allograft-Prosthesis Composite Reconstructions},
  journal = {Sarcoma},
  year = {2013},
  volume = {2013},
  pages = {1--8},
  doi = {10.1155/2013/489652}
}
Kostenlos starten →