Enabling 3D-Liver Perfusion Mapping from MR-DCE Imaging Using Distributed Computing
Journal of Medical Engineering · 2013
DOI: 10.1155/2013/471682 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Engineering, 2013. Verfasst von Benjamin Leporq und 4 weiteren Autor:innen. Beteiligte Einrichtung: Université de Lyon, CREATIS, CNRS UMR 5220, Inserm U1044, INSA-Lyon, Université Lyon 1, 69622 Villeurbanne Cedex, France. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
An MR acquisition protocol and a processing method using distributed computing on the European Grid Infrastructure (EGI) to allow 3D liver perfusion parametric mapping after Magnetic Resonance Dynamic Contrast Enhanced (MR-DCE) imaging are presented. Seven patients (one healthy control and six with chronic liver diseases) were prospectively enrolled after liver biopsy. MR-dynamic acquisition was continuously performed in free-breathing during two minutes after simultaneous intravascular contrast agent (MS-325 blood pool agent) injection. Hepatic capillary system was modeled by a 3-parameters one-compartment pharmacokinetic model. The processing step was parallelized and executed on the EGI. It was modeled and implemented as a grid workflow using the Gwendia language and the MOTEUR workflow engine. Results showed good reproducibility in repeated processing on the grid. The results obtained from the grid were well correlated with ROI-based reference method ran locally on a personal computer. The speed-up range was 71 to 242 with an average value of 126. In conclusion, distributed computing applied to perfusion mapping brings significant speed-up to quantification step to be used for further clinical studies in a research context. Accuracy would be improved with higher image SNR accessible on the latest 3T MR systems available today.
Autor:innen und Institutionen
- Université de Lyon, CREATIS, CNRS UMR 5220, Inserm U1044, INSA-Lyon, Université Lyon 1, 69622 Villeurbanne Cedex, France.
- Université de Lyon, CREATIS, CNRS UMR 5220, Inserm U1044, INSA-Lyon, Université Lyon 1, 69622 Villeurbanne Cedex, France; Departement d'imagerie Digestive, Hospices Civils de Lyon, CHU Edouard Herriot, 69008 Lyon, Franc…
Zitieren
APA
Leporq, B., Camarasu-Pop, S., Davila-Serrano, E. E., Pilleul, F., & Beuf, O. (2013). Enabling 3D-Liver Perfusion Mapping from MR-DCE Imaging Using Distributed Computing. Journal of Medical Engineering. https://doi.org/10.1155/2013/471682
Vancouver
Leporq B, Camarasu-Pop S, Davila-Serrano EE, Pilleul F, Beuf O. Enabling 3D-Liver Perfusion Mapping from MR-DCE Imaging Using Distributed Computing. Journal of Medical Engineering. 2013. doi:10.1155/2013/471682
BibTeX
@article{Leporq2013,
author = {Leporq, Benjamin and Camarasu-Pop, Sorina and Davila-Serrano, Eduardo E and Pilleul, Frank and Beuf, Olivier},
title = {Enabling 3D-Liver Perfusion Mapping from MR-DCE Imaging Using Distributed Computing},
journal = {Journal of Medical Engineering},
year = {2013},
doi = {10.1155/2013/471682}
}
EUVIMED