Fachartikel in der Zeitschrift ISRN Obesity, 2013. Verfasst von Jean-Claude Pineau und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Human Evolution, French National Center for Scientific Research, UPR 2147-CNRS, 44 Amiral Mouchez Street, 75014 Paris, France. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To examine measurement of body composition by ultrasound compared with a reference technique:dual energy X-ray absorptiometry (DXA). We evaluated the accuracy of a portable ultrasound-based device in estimating total body fat mass with those assessed by DXA in adult.

Methods

Body fat mass has been estimated using a portable ultrasound-based device in comparison with a contemporary reference DXA apparatus: the Hologic Discovery A. Anthropometric data has been assessed in order to maximize the output of the software associated with the ultrasound-based device. A cross-validation between ultrasound technique (US) and DXA was developed in this study. Total body fat mass estimated by ultrasound was compared with this DXA model in a sample of 83 women and 41 men.

Results

Ultrasound technique (US) of body fat (BF) was better correlated with DXA in both women ( r 2 = 0.97 , P < 0.01 ) and men ( r 2 = 0.92 , P < 0.01 ) with standard errors of estimates (SEE) being 2.1 kg and 2.2 kg, respectively.

Conclusion

The use of a portable device based on a US produced a very accurate BF estimate in relation to DXA reference technique. As DXA absorptiometry techniques are not interchangeable, the use of our ultrasound-based device needs to be recalibrated on a more contemporary DXA.

Autor:innen und Institutionen

  • Department of Human Evolution, French National Center for Scientific Research, UPR 2147-CNRS, 44 Amiral Mouchez Street, 75014 Paris, France.
  • Department of Public Health Sciences ,University of Modena and Reggio Emilia, Campi Road 287, 41100 Modena, Italy.

Zitieren

APA

Pineau, J. C., Lalys, L., Pellegrini, M., & Battistini, N. C. (2013). Body Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model of DXA. ISRN Obesity. https://doi.org/10.1155/2013/462394

Vancouver

Pineau JC, Lalys L, Pellegrini M, Battistini NC. Body Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model of DXA. ISRN Obesity. 2013. doi:10.1155/2013/462394

BibTeX
@article{Pineau2013,
  author = {Pineau, Jean-Claude and Lalys, Loïc and Pellegrini, Massimo and Battistini, Nino Carlo},
  title = {Body Fat Mass Assessment: A Comparison between an Ultrasound-Based Device and a Discovery A Model of DXA},
  journal = {ISRN Obesity},
  year = {2013},
  doi = {10.1155/2013/462394}
}
Kostenlos starten →