The Retroacetabular Angle Determines the Safe Angle for Screw Placement in Posterior Acetabular Fracture Fixation
ISRN Orthopedics · 2013
DOI: 10.1155/2013/432675 ↗Kurz gefasst
Fachartikel in der Zeitschrift ISRN Orthopedics, 2013. Verfasst von Ayman M A Tadros und 2 weiteren Autor:innen. Beteiligte Einrichtung: Trauma Division, Orthopaedic Department, University of BC, British Columbia, Canada ; Orthopaedic Department, Mafraq Hospital, Abu Dhabi, UAE. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Introduction
A method for the determination of safe angles for screws placed in the posterior acetabular wall based on preoperative computed tomography (CT) is described. It defines a retroacetabular angle and determines its variation in the population.
Methods
The retroacetabular angle is the angle between the retroacetabular surface and the tangent to the posterior acetabular articular surface. Screws placed through the marginal posterior wall at an angle equal to the retroacetabular angle are extraarticular. Medial screws can be placed at larger angles whose difference from the retroacetabular angle is defined as the allowance angles. CT scans of all patients with acetabular fractures treated in our institute between September 2002 to July 2007 were used to measure the retroacetabular angle and tangent.
Results
Two hundred thirty one patients were included. The average (range) age was 42 (15–74) years. The average (range) retroacetabular angle was 39 (30–47) degrees. The average (range) retroacetabular tangent was 36 (30–45) mm.
Conclusions
Placing the screws at an average (range) angle of 39 (33–47) degrees of anterior inclination with the retroacetabular surface makes them extraarticular. Angles for medial screws are larger. Safe angles can be calculated preoperatively with a computer program.
Autor:innen und Institutionen
- Trauma Division, Orthopaedic Department, University of BC, British Columbia, Canada ; Orthopaedic Department, Mafraq Hospital, Abu Dhabi, UAE.
- Division of Orthopaedic Engineering Research, Departments of Orthopaedics and Mechanical Engineering, University of British Columbia, BC, Canada.
- Trauma Division, Orthopaedic Department, University of BC, British Columbia, Canada.
Zitieren
APA
Tadros, A. M., Oxland, T. R., & O'Brien, P. (2013). The Retroacetabular Angle Determines the Safe Angle for Screw Placement in Posterior Acetabular Fracture Fixation. ISRN Orthopedics. https://doi.org/10.1155/2013/432675
Vancouver
Tadros AM, Oxland TR, O'Brien P. The Retroacetabular Angle Determines the Safe Angle for Screw Placement in Posterior Acetabular Fracture Fixation. ISRN Orthopedics. 2013. doi:10.1155/2013/432675
BibTeX
@article{Tadros2013,
author = {Tadros, Ayman M A and Oxland, Thomas R and O'Brien, Peter},
title = {The Retroacetabular Angle Determines the Safe Angle for Screw Placement in Posterior Acetabular Fracture Fixation},
journal = {ISRN Orthopedics},
year = {2013},
doi = {10.1155/2013/432675}
}
EUVIMED