EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study

Stefan Maas, Arnaud Diffo Kaze iD, Klaus Dueck, Dietrich Pape

ISRN Orthopedics · 2013

DOI: 10.1155/2013/387620 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ISRN Orthopedics, 2013. Verfasst von Stefan Maas und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Science, Technology and Communication, University of Luxembourg, 6 rue R. Coudenhove-Kalergi, 1359 Luxembourg, Luxembourg. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The objective of the present study was to compare mechanical strength and stability of the newly designed spacer plate with the gold standard plate for the treatment of medial knee joint osteoarthritis. Materials and Methods . Ten fourth-generation tibial bone composites underwent a medial open-wedge high tibial osteotomy (HTO) according to standard techniques, using five TomoFix plates and five Contour Lock plates. Static compression load to failure and load-controlled cyclical fatigue failure tests were performed. Forces and horizontal displacements were measured; plastic deformations and dynamic stiffness were determined. Results and Discussion . In all samples, rotation of the tibial head and fracture of the opposite cortex were observed. Behaviors of the specimens under static loading were comparable between groups. Cyclic testing revealed lateral significant higher stiffness until failure for the Contour Lock compared to the TomoFix plate. No visible implant failure was observed in any group.

Conclusion

Considering the static analysis, both plates offered sufficient stability under physiologic loads of up to 3000 N. The Contour Lock plate-fixated specimens showed a higher stability during the cyclic testing, supposedly due to the wider distance between the fixation screws.

Autor:innen und Institutionen

  • Faculty of Science, Technology and Communication, University of Luxembourg, 6 rue R. Coudenhove-Kalergi, 1359 Luxembourg, Luxembourg.
  • Department of Orthopedic Surgery, Centre Hospitalier de Luxembourg, 78 rue d'Eich, 1460 Luxembourg, Luxembourg.
  • Department of Orthopedic Surgery, Centre Hospitalier de Luxembourg, 78 rue d'Eich, 1460 Luxembourg, Luxembourg ; Sports Medicine Research Laboratory, Public Research Centre for Health, Centre Médical de la Fondation Nor…

ORCID-Profile: Arnaud Diffo Kaze

Zitieren

APA

Maas, S., Diffo Kaze, A., Dueck, K., & Pape, D. (2013). Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study. ISRN Orthopedics. https://doi.org/10.1155/2013/387620

Vancouver

Maas S, Diffo Kaze A, Dueck K, Pape D. Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study. ISRN Orthopedics. 2013. doi:10.1155/2013/387620

BibTeX
@article{Maas2013,
  author = {Maas, Stefan and Diffo Kaze, Arnaud and Dueck, Klaus and Pape, Dietrich},
  title = {Static and Dynamic Differences in Fixation Stability between a Spacer Plate and a Small Stature Plate Fixator Used for High Tibial Osteotomies: A Biomechanical Bone Composite Study},
  journal = {ISRN Orthopedics},
  year = {2013},
  doi = {10.1155/2013/387620}
}
Kostenlos starten →