Markerless Lung Tumor Motion Tracking by Dynamic Decomposition of X-Ray Image Intensity

Noriyasu Homma iD, Yoshihiro Takai, Haruna Endo, Kei Ichiji iD, Yuichiro Narita, Xiaoyong Zhang, Masao Sakai, Makoto Osanai, Makoto Abe, Norihiro Sugita iD, Makoto Yoshizawa

Journal of Medical Engineering · 2013

DOI: 10.1155/2013/340821 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Engineering, 2013. Verfasst von Noriyasu Homma und 10 weiteren Autor:innen. Beteiligte Einrichtung: Tohoku University Graduate School of Medicine, Sendai 980-8575, Japan. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Japan Science and Technology Agency.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We propose a new markerless tracking technique of lung tumor motion by using an X-ray fluoroscopic image sequence for real-time image-guided radiation therapy (IGRT). A core innovation of the new technique is to extract a moving tumor intensity component from the fluoroscopic image intensity. The fluoroscopic intensity is the superimposition of intensity components of all the structures passed through by the X-ray. The tumor can then be extracted by decomposing the fluoroscopic intensity into the tumor intensity component and the others. The decomposition problem for more than two structures is ill posed, but it can be transformed into a well-posed one by temporally accumulating constraints that must be satisfied by the decomposed moving tumor component and the rest of the intensity components. The extracted tumor image can then be used to achieve accurate tumor motion tracking without implanted markers that are widely used in the current tracking techniques. The performance evaluation showed that the extraction error was sufficiently small and the extracted tumor tracking achieved a high and sufficient accuracy less than 1 mm for clinical datasets. These results clearly demonstrate the usefulness of the proposed method for markerless tumor motion tracking.

Autor:innen und Institutionen

  • Tohoku University Graduate School of Medicine, Sendai 980-8575, Japan.
  • Hirosaki University Graduate School of Medicine, Hirosaki 036-8562, Japan.
  • St. Luke's International Hospital, Tokyo 104-8560, Japan.
  • Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan.
  • Center for Information Technology in Education, Tohoku University, Sendai 980-8576, Japan.
  • Cyberscience Center, Tohoku University, Sendai 980-8578, Japan.

ORCID-Profile: Noriyasu Homma, Kei Ichiji, Norihiro Sugita

Förderung

  • Japan Science and Technology Agency

Zitieren

APA

Homma, N., Takai, Y., Endo, H., Ichiji, K., Narita, Y., Zhang, X., Sakai, M., Osanai, M., Abe, M., Sugita, N., & Yoshizawa, M. (2013). Markerless Lung Tumor Motion Tracking by Dynamic Decomposition of X-Ray Image Intensity. Journal of Medical Engineering. https://doi.org/10.1155/2013/340821

Vancouver

Homma N, Takai Y, Endo H, Ichiji K, Narita Y, Zhang X, et al. Markerless Lung Tumor Motion Tracking by Dynamic Decomposition of X-Ray Image Intensity. Journal of Medical Engineering. 2013. doi:10.1155/2013/340821

BibTeX
@article{Homma2013,
  author = {Homma, Noriyasu and Takai, Yoshihiro and Endo, Haruna and Ichiji, Kei and Narita, Yuichiro and Zhang, Xiaoyong and Sakai, Masao and Osanai, Makoto and Abe, Makoto and Sugita, Norihiro and Yoshizawa, Makoto},
  title = {Markerless Lung Tumor Motion Tracking by Dynamic Decomposition of X-Ray Image Intensity},
  journal = {Journal of Medical Engineering},
  year = {2013},
  doi = {10.1155/2013/340821}
}
Kostenlos starten →