Breakage of Needle during Intracavernosal Injection and Use of Portable Ultrasound Guidance for Removal
Case Reports in Urology · 2013 · 2013 · 1-3
DOI: 10.1155/2013/215492 ↗Kurz gefasst
Fachartikel in der Zeitschrift Case Reports in Urology, 2013. Verfasst von Wayland Hsiao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Emory University School of Medicine, Atlanta, GA 30322, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Purpose
Intracavernosal self-injection (ICI) was first described in 1982, and remains a viable therapy for erectile dysfunction. However, intracorporal needle breakage can be a rare complication of therapy. We report a rare complication of intracorporal needle breakage and a retention of a 30-gauge needle in a 42-year-old paraplegic man. We discuss our experience in using portable high-frequency ultrasound intraoperatively to visualize and guide removal of a retained ICI needle. Materials and Methods . Review of case and ultrasound technique are presented.
Results
Using intraoperative ultrasound imaging, the retained intracorporal needle was successfully removed from the patient's penis without any complications. Follow-up ultrasonography and X-ray confirmed complete removal of the needle.
Conclusions
We report on the successful implementation and use of a portable high-frequency ultrasound probe to visualize a retained intracorporal needle inside the penis and its use to guide removal. Given the rapid proliferation of portable ultrasound machines in the operating room and out in the field, we expect these imaging techniques to become routine, especially in urological emergencies.
Autor:innen und Institutionen
- Department of Urology, Emory University School of Medicine, Atlanta, GA 30322, USA.
Zitieren
APA
Hsiao, W., Lian, F., Goodgame, B., Ritenour, C. W., Angell, J., & Master, V. A. (2013). Breakage of Needle during Intracavernosal Injection and Use of Portable Ultrasound Guidance for Removal. Case Reports in Urology, 2013, 1-3. https://doi.org/10.1155/2013/215492
Vancouver
Hsiao W, Lian F, Goodgame B, Ritenour CW, Angell J, Master VA. Breakage of Needle during Intracavernosal Injection and Use of Portable Ultrasound Guidance for Removal. Case Reports in Urology. 2013;2013:1-3. doi:10.1155/2013/215492
BibTeX
@article{Hsiao2013,
author = {Hsiao, Wayland and Lian, Fei and Goodgame, Brooks and Ritenour, Chad W M and Angell, Jordan and Master, Viraj A},
title = {Breakage of Needle during Intracavernosal Injection and Use of Portable Ultrasound Guidance for Removal},
journal = {Case Reports in Urology},
year = {2013},
volume = {2013},
pages = {1--3},
doi = {10.1155/2013/215492}
}
EUVIMED