EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Evaluation of Harmonic Content from a Tap Transformer Based Grid Connection System for Wind Power

S. Apelfröjd, S. Eriksson

Journal of Renewable Energy · 2013

DOI: 10.1155/2013/190573 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Renewable Energy, 2013. Verfasst von S. Apelfröjd und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Simulations done in MATLAB/Simulink together with experiments conducted at the Ångströms laboratory are used to evaluate and discuss the total harmonic distortion (THD) and total demand distortion (TDD) of a tap transformer based grid connection system. The grid connection topology can be used with different turbine and generator topologies and is here applied on a vertical axis wind turbine (VAWT) with a permanent magnet synchronous generator (PMSG) and its operational scheme. The full variable-speed wind conversion system consists of a diode rectifier, DC link, IGBT inverter, LCL-filter, and tap transformer. The full variable-speed operation is enabled by the use of the different step-up ratios of the tap transformer. In the laboratory study, a full experimental setup of the system was used, a clone of the on-site PMSG driven by a motor was used, and the grid was replaced with a resistive load. With a resistive load, grid harmonics and possible unbalances are removed. The results show a TDD and THD below 5% for the full operating range and harmonic values within the limits set up by IEEE-519. Furthermore, a change in tap, going to a lower step-up ratio, results in a reduction in both THD and TDD for the same output power.

Zitieren

APA

Apelfröjd, S., & Eriksson, S. (2013). Evaluation of Harmonic Content from a Tap Transformer Based Grid Connection System for Wind Power. Journal of Renewable Energy. https://doi.org/10.1155/2013/190573

Vancouver

Apelfröjd S, Eriksson S. Evaluation of Harmonic Content from a Tap Transformer Based Grid Connection System for Wind Power. Journal of Renewable Energy. 2013. doi:10.1155/2013/190573

BibTeX
@article{Apelfrjd2013,
  author = {Apelfröjd, S. and Eriksson, S.},
  title = {Evaluation of Harmonic Content from a Tap Transformer Based Grid Connection System for Wind Power},
  journal = {Journal of Renewable Energy},
  year = {2013},
  doi = {10.1155/2013/190573}
}
Kostenlos starten →