Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates
ISRN Orthopedics · 2013
DOI: 10.1155/2013/131757 ↗Kurz gefasst
Fachartikel in der Zeitschrift ISRN Orthopedics, 2013. Verfasst von Paritosh Gogna und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Rehabilitation, Pt. B.D. Sharma Post graduate Institute of Medical Sciences, 2/11-J Medical Enclave, PGIMS, Haryana, R…. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Background
Dorsally comminuted distal radius fractures are unstable fractures and represent a treatment challenge. The objective of this study was to evaluate the functional and radiological outcome of dorsally comminuted fractures of the distal radius fixed with a volar locking plate. Patients and Methods . Thirty-three consecutive patients with dorsally comminuted fractures of the distal end of the radius were treated by open reduction and internal fixation with AO 2.4 mm ( n = 19 )/3.5 mm ( n = 14 ) volar locking distal radius plate (Synthes, Switzerland, marketed by Synthes India Pvt. Ltd.). There were 7 type A3, 8 type C2, and 18 type C3 fractures. The patients were followed up at 6 weeks, 3 months, 6 months, and 1 year postoperatively. Subjective assessment was done as per Disabilities Arm, Shoulder, and Hand (DASH) questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist; the radiological determinants were radial angle, radial length, volar angle, and ulnar variance. The final assessment was done as per Demerit point system of Saito.
Results
There were 23 males and 10 females with an average age of 44.12 ± 18.63 years (18–61 years). Clinicoradiological consolidation of the fracture was observed in all cases at a mean of 9.6 weeks (range 7–12 weeks). The average final extension was 58.15° ± 7.83°, flexion was 54.62° ± 11.23°, supination was 84.23° ± 6.02°, and pronation was 80.92° ± 5.54°. Demerit point system of Saito yielded excellent results in 79% ( n = 26 ), good in 18% ( n = 6 ), and fair in 3% ( n = 1 ) patients. Three patients had loss of reduction but none of the patients had tendon irritation or ruptures, implant failure, or nonunion at the end of an one-year followup.
Conclusion
Volar locking plate fixation for dorsally comminuted distal radius fractures results in good to excellent functional outcomes despite a high incidence of loss of reduction and fracture collapse.
Autor:innen und Institutionen
- Department of Orthopaedics and Rehabilitation, Pt. B.D. Sharma Post graduate Institute of Medical Sciences, 2/11-J Medical Enclave, PGIMS, Haryana, Rohtak 124001, India.
- Department of Orthopaedics, Dayanand Medical College and Hospital, Punjab, Ludhiana 141001, India.
ORCID-Profile: Paritosh Gogna, Rohit Singla, Pankaj Mahindra
Zitieren
APA
Gogna, P., Selhi, H. S., Singla, R., Devgan, A., Magu, N. K., Mahindra, P., & Yamin, M. (2013). Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates. ISRN Orthopedics. https://doi.org/10.1155/2013/131757
Vancouver
Gogna P, Selhi HS, Singla R, Devgan A, Magu NK, Mahindra P, et al. Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates. ISRN Orthopedics. 2013. doi:10.1155/2013/131757
BibTeX
@article{Gogna2013,
author = {Gogna, Paritosh and Selhi, Harpal Singh and Singla, Rohit and Devgan, Ashish and Magu, Narender Kumar and Mahindra, Pankaj and Yamin, Mohammad},
title = {Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates},
journal = {ISRN Orthopedics},
year = {2013},
doi = {10.1155/2013/131757}
}
EUVIMED