Automated Measurement of Immature Granulocytes: Performance Characteristics and Utility in Routine Clinical Practice
Pathology Research International · 2012
DOI: 10.1155/2012/483670 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pathology Research International, 2012. Verfasst von Balamurugan Senthilnayagam und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Chettinad Deemed University, Padur, Kancheepuram 603103, India. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Indian Council for Medical Research.
Abstract (Originalsprache)
The granulocytic “shift to left” reflects marrow response to bacterial infection, and this may be quantified as band count or immature granulocyte count (IGC). The former value, used widely in neonatal sepsis, has been notoriously difficult to measure accurately and precisely. A reproducible, precise, and accurate counting of immature granulocyte counts may be possible with automation. This study of 200 febrile patients aimed at analysing the performance characteristics of automated immature granulocytes (AIGs) in predicting blood culture and their clinical utility. The absolute (IGC) and relative IG count (IG%) had area under curve (AUC) of 0.69 and 0.66. Moreover, the means of IGC and IG% between culture positive and negative groups were statistically significant suggesting that they are potential markers for bacteremia. IGC of 0.03 × 10 3 cu⋅mm and IG% of 0.5% offered sensitivity of 86.3% and 92.2%, respectively, and may be used for screening for bacteremia. Higher values, IGC > 0.3, and IG% > 3 had specificity greater than 90%, although the values were infrequent. It may not be long before that these automated hemograms are put into regular diagnostic use.
Autor:innen und Institutionen
- Department of Pathology, Chettinad Deemed University, Padur, Kancheepuram 603103, India.
Förderung
- Indian Council for Medical Research
Zitieren
APA
Senthilnayagam, B., Kumar, T., Sukumaran, J., M, J., & Rao K, R. (2012). Automated Measurement of Immature Granulocytes: Performance Characteristics and Utility in Routine Clinical Practice. Pathology Research International. https://doi.org/10.1155/2012/483670
Vancouver
Senthilnayagam B, Kumar T, Sukumaran J, M J, Rao K R. Automated Measurement of Immature Granulocytes: Performance Characteristics and Utility in Routine Clinical Practice. Pathology Research International. 2012. doi:10.1155/2012/483670
BibTeX
@article{Senthilnayagam2012,
author = {Senthilnayagam, Balamurugan and Kumar, Treshul and Sukumaran, Jayapriya and M, Jeya and Rao K, Ramesh},
title = {Automated Measurement of Immature Granulocytes: Performance Characteristics and Utility in Routine Clinical Practice},
journal = {Pathology Research International},
year = {2012},
doi = {10.1155/2012/483670}
}
EUVIMED